Koay A S, Jegathesan M, Rohani M Y, Cheong Y M
Bacteriology Division, Institute for Medical Research, Kuala Lumpur, Malaysia.
Southeast Asian J Trop Med Public Health. 1997 Mar;28(1):82-4.
Strains of Salmonella typhi implicated in two separate cases of laboratory acquired infection from patients and the medical laboratory technologists who processed the patients' samples were analysed by pulsed-field gel electrophoresis. Although all four isolates were of bacteriophage type E1, PFGE was able to demonstrate that the strains responsible for the two laboratory acquired cases were not genetically related. The PFGE patterns of the isolates from the MLTs were found to be identical to those of the corresponding patients after digestion with restriction enzyme AvrII. This provided genetic as well as epidemiological evidence for the source of the laboratory acquired infections.
对两例分别由患者引发的实验室感染病例中的伤寒沙门氏菌菌株,以及处理患者样本的医学实验室技术人员进行了脉冲场凝胶电泳分析。尽管所有四个分离株均为噬菌体E1型,但脉冲场凝胶电泳能够证明导致两例实验室感染病例的菌株在基因上并无关联。在用限制性内切酶AvrII消化后,发现医学实验室技术人员分离株的脉冲场凝胶电泳图谱与相应患者的图谱相同。这为实验室感染的源头提供了遗传学和流行病学证据。