Although RARE and GRASE can produce single-shot images of excellent quality, their utility has been restricted because preparation of the magnetization with interesting contrast before imaging can cause severe artifacts. These artifacts relate to the strong sensitivity of multiple spin echo sequences to the phase of the prepared magnetization. Modifications of the RARE sequence to eliminate these artifacts are discussed, and an approach that eliminates the artifact producing signals from the very first echo is presented. The approach is applied to diffusion imaging of the human brain in normal volunteers and one patient.
尽管RARE和GRASE能够生成高质量的单次激发图像,但其应用受到限制,因为在成像前准备具有感兴趣对比度的磁化会导致严重伪影。这些伪影与多自旋回波序列对准备好的磁化相位的高度敏感性有关。文中讨论了对RARE序列进行修改以消除这些伪影的方法,并提出了一种从第一个回波就消除产生伪影信号的方法。该方法应用于正常志愿者和一名患者的人脑扩散成像。