Nakao A, Yasui M, Kawagoe T, Tamura H, Tanaka S, Takagi H
Department of Surgery II, Nagoya University School of Medicine, Japan.
Hepatogastroenterology. 1997 Sep-Oct;44(17):1413-8.
BACKGROUND/AIMS: The purpose of this study was to evaluate the occurrence of false-positive endotoxemia after hepatectomy for hepatocellular carcinoma in patients with cirrhosis. The chromogenic conventional limulus test (Toxicolor test) revealed transiently increased blood endotoxin levels after hepatic resection for hepatocellular carcinoma in patients with liver cirrhosis. However, clinical signs of endotoxemia were not observed in all of the cases.
Pre- and postoperative changes of blood endotoxin levels and beta-glucan were measured in 20 patients with liver cirrhosis who underwent hepatic resection for hepatocellular carcinoma, using the Toxicolor test, the Endospecy test (which specifically reacts with endotoxin) and the Gluspecy test (which specifically reacts with beta-glucan). The changes in endotoxin levels and beta-glucan in ascitic fluid during surgery were also studied.
The Toxicolor test revealed transiently increased blood endotoxin levels, but Endospecy test results were not elevated. The changes in the Gluspecy test were almost the same as in the Toxicolor test. During surgery, beta-glucan levels in the ascitic fluid increased remarkably due to their release from the surgical gauze. Digestion studies using 1-3-beta-D-glucanase on specimens which showed high Toxicolor and Gluspecy test values resulted in a lack of response for both tests.
The cause of false-positive endotoxemia was determined to be caused by beta-glucan, which was released from the surgical gauze.
背景/目的:本研究旨在评估肝硬化患者肝细胞癌肝切除术后假阳性内毒素血症的发生情况。显色鲎试剂常规检测(Toxicolor检测)显示,肝硬化患者肝细胞癌肝切除术后血液内毒素水平短暂升高。然而,并非所有病例都观察到内毒素血症的临床症状。
对20例行肝细胞癌肝切除术的肝硬化患者,采用Toxicolor检测、Endospecy检测(与内毒素特异性反应)和Gluspecy检测(与β-葡聚糖特异性反应),测定术前和术后血液内毒素水平及β-葡聚糖的变化。同时研究手术过程中腹水内毒素水平和β-葡聚糖的变化。
Toxicolor检测显示血液内毒素水平短暂升高,但Endospecy检测结果未升高。Gluspecy检测的变化与Toxicolor检测几乎相同。手术过程中,由于手术纱布释放β-葡聚糖,腹水内β-葡聚糖水平显著升高。对Toxicolor和Gluspecy检测值高的标本进行1-3-β-D-葡聚糖酶消化研究,结果显示两种检测均无反应。
假阳性内毒素血症的原因被确定为由手术纱布释放的β-葡聚糖引起。