Ostergaard M, Kristensen B B, Mogensen T S
H:S Hvidovre Hospital, anaestesiologisk afdeling.
Ugeskr Laeger. 1997 Nov 10;159(46):6835-6.
We report a unilateral lingual nerve paralysis following the use of a laryngeal mask airway in a 73-year-old man with hypertrophy of the prostate undergoing a TUR-P. The operation was performed in general anaesthesia using propofol, fentanyl, alfentanil and ventilation with 100% oxygen. The operation was uncomplicated and had a duration of two hours and twenty minutes. A week later the patient perceived a reduced sense of taste. Six months later the situation was unaltered.