HPLC/circular dichroism detection using a conventional spectrophotometric detector has been established. A split-type flow cell developed for a polarized photometric detector, which is a non-modulated polarimeter, was inserted into this detector. When two rays of circularly polarized light with opposite rotational senses to each other were incident in both cells by combining a polarizer and a 1/4 wave retarder in front of the cell assembly, the output from this spectrophotometric detector became solely the signal based on circular dichroism. Selective detection of a chiral analyte, in which the ratio of the difference in the absorbance between two rays mentioned above and the absorbance by normal rays in over 1/1000, is feasible using the proposed instrument.

摘要

已建立使用常规分光光度检测器的高效液相色谱/圆二色检测法。将为偏振光度检测器(一种非调制旋光仪)开发的分体式流通池插入该检测器中。当通过在流通池组件前组合偏振器和四分之一波片使两条旋转方向相反的圆偏振光入射到两个流通池中时,该分光光度检测器的输出仅变为基于圆二色性的信号。使用所提出的仪器可以选择性地检测手性分析物,其中上述两条光线之间的吸光度差异与正常光线的吸光度之比超过千分之一。