Is there a need for a revised table of equivalent square fields for the determination of phantom scatter correction factors?

作者信息

Venselaar J L, Heukelom S, Jager H N, Mijnheer B J, van Gasteren J J, van Kleffens H J, van der Laarse R, Westermann C F

机构信息

Dr B Verbeeten Institute, Tilburg, The Netherlands.

出版信息

Phys Med Biol. 1997 Dec;42(12):2369-81. doi: 10.1088/0031-9155/42/12/005.

DOI:10.1088/0031-9155/42/12/005
PMID:9434294
Abstract

The use of the British Journal of Radiology (BJR) (supplement 17) tables of equivalent square fields for dose calculations is widespread. A revised version of the supplement was published recently, with a more elaborate discussion, but without changes in data given in these tables (Br. J. Radiol. suppl 25). The tables were generated for use in dose calculations, with relative beam data such as PDD, BSF, PSF, all with d(max) as the reference depth. However, the current philosophy in dose calculational methods is based on quantities defined at a reference depth, d(ref) = 10 cm, on a separation of phantom and head scatter, and on the use of the relative depth-dose or tissue-phantom ratios normalized at d(ref). By using these quantities as a starting point, problems at shallow depths related to the influence of contaminating electrons in the beam can be eliminated. Recently, a comprehensive set of phantom scatter factor data with d(ref) = 10 cm has been published for a set of square field sizes and a wide range of photon beam energies, showing that phantom scatter is a smoothly varying function of field size and quality index. It is not a priori evident that the conventional concept of equivalent squares for rectangular fields is also fully applicable for phantom scatter factors and phantom scatter related quantities at a depth of 10 cm. It was questioned whether or not new tables of equivalent square fields are needed for this purpose. In this paper, new tables have been constructed for four photon beam energies in the range of Co-60 to 25 MV (quality index from 0.572 to 0.783). The small differences between the outcome of these new tables allowed the construction of one averaged table of equivalent square fields. Phantom scatter factors were calculated for rectangular fields based on the use of the BJR table and on the use of the newly constructed tables and the differences were quantified. For Co-60 no improvements could be shown when using the new averaged table, but for beam energies of 6 to 10 MV small improvements of the order of 0.5 to 1.0% were found. For a higher beam energy of 25 MV the improvement is smaller. Deviations resulting from the BJR table are within the limits of accuracy as stated by the authors. Therefore, for clinical use, the continued use of the BJR table of equivalent squares for phantom scatter factors and phantom scatter related quantities of rectangular fields is justified, irrespective of photon beam energy.

摘要

相似文献

1
Is there a need for a revised table of equivalent square fields for the determination of phantom scatter correction factors?
Phys Med Biol. 1997 Dec;42(12):2369-81. doi: 10.1088/0031-9155/42/12/005.
2
Equivalent squares of irregular photon fields.不规则光子野的等效方野
Med Phys. 1993 Jul-Aug;20(4):1229-32. doi: 10.1118/1.596973.
3
Determination of equivalent photon fields through integrated 1D convolution kernels.通过积分一维卷积核对等效光子场的测定。
Phys Med Biol. 1999 Dec;44(12):2971-85. doi: 10.1088/0031-9155/44/12/309.
4
Technical note: Determining equivalent squares of high-energetic photon fields.技术说明:确定高能光子场的等效面积。
Med Phys. 2023 Feb;50(2):1242-1250. doi: 10.1002/mp.16069. Epub 2022 Dec 26.
5
Comparison of the ESTRO formalism for monitor unit calculation with a Clarkson based algorithm of a treatment planning system and a traditional "full-scatter" methodology.用于剂量监测单位计算的欧洲放射治疗及肿瘤学组织(ESTRO)形式主义与治疗计划系统基于克拉克森算法以及传统“全散射”方法的比较。
Z Med Phys. 2005;15(4):235-46. doi: 10.1078/0939-3889-00280.
6
A consistent formalism for the application of phantom and collimator scatter factors.
Phys Med Biol. 1999 Feb;44(2):365-81. doi: 10.1088/0031-9155/44/2/006.
7
Theoretical and experimental determination of phantom scatter factors for photon fields with different radial energy variation.不同径向能量变化的光子场体模散射因子的理论与实验测定
Phys Med Biol. 1996 Dec;41(12):2687-94. doi: 10.1088/0031-9155/41/12/008.
8
Accuracy limits of the equivalent field method for irregular photon fields.不规则光子射野等效射野法的精度限制
Phys Med Biol. 2002 Sep 7;47(17):3073-85. doi: 10.1088/0031-9155/47/17/303.
9
Monte Carlo dose calculations for radiotherapy machines: Theratron 780-C teletherapy case study.放射治疗设备的蒙特卡罗剂量计算:Theratron 780-C远距离治疗案例研究。
Phys Med Biol. 2004 Mar 7;49(5):807-18. doi: 10.1088/0031-9155/49/5/011.
10
"Zero-field" dose data for 60Co and other high-energy photon beams in water.水中60Co及其他高能光子束的“零场”剂量数据。
Med Phys. 1993 Sep-Oct;20(5):1353-60. doi: 10.1118/1.597155.

引用本文的文献

1
An Analytical Method to Calculate Phantom Scatter Factor for Photon Beam Accelerators.一种计算光子束加速器体模散射因子的分析方法。
Electron Physician. 2017 Jan 25;9(1):3523-3528. doi: 10.19082/3523. eCollection 2017 Jan.
2
A simple calculation method for determination of equivalent square field.一种用于确定等效方野的简单计算方法。
J Med Phys. 2012 Apr;37(2):107-11. doi: 10.4103/0971-6203.94746.
3
A generalized calibration procedure for in vivo transit dosimetry using siemens electronic portal imaging devices.使用西门子电子射野影像系统进行体内传输剂量学的通用校准程序。
Med Biol Eng Comput. 2011 Mar;49(3):373-83. doi: 10.1007/s11517-010-0699-6. Epub 2010 Nov 4.