Suppr超能文献

[Radiation exposure of the ocular lens and thyroid gland in digital subtraction angiography of brain-supplying arteries].

作者信息

Heyne J P, Schleicher C, Söldner J, Neumann R, Kaiser W A

机构信息

Institut für Diagnostische und Interventionelle Radiologie, Friedrich-Schiller-Universität Jena.

出版信息

Rofo. 1997 Nov;167(5):479-85. doi: 10.1055/s-2007-1015567.

Abstract

PURPOSE

To find out the individual level of radiation exposure of the ocular lens and thyroid gland during DSA of arteries supplying the brain, considering the indication.

MATERIAL AND METHOD

The study was conducted on 72 patients during aortic arch and cerebral artery angiographies using thermoluminescent dosimetry.

RESULTS

During 20 aortic arch angiographies the measured values were within non-critical limits, whereas during carotid, vertebral or cerebral four-vessel angiography of the left ocular lens exposure values of more than 500 mGy (max. 782 mGy) were stated in two of 52 cases. The highest measured exposure relating to the right ocular lens was 126 mGy, to the thyroid gland 88 mGy. However, in 51 of 52 cases thyroid gland doses of below 51 mGy were measured. In 71 of 72 cases there was a lateral difference between right and left lens exposure up to twice the measured dose for the right ocular lens during aortic arch angiographies and up to sixteen-fold in respect of the left lens during cerebral angiographies.

CONCLUSION

In addition to the fluoroscopic time, number of images, fade-in and zoom some other dose-influencing factors, radiation geometry is especially decisive for organ exposure. The risk of cataracts or thyroid gland carcinomas/hypothyrosis can be neglected with median values of 40 and 70 mGy relating to the ocular lens and 17 mGy for the thyroid gland during cerebral angiographies.

摘要

相似文献

3
Organ doses from cardiac and carotid digital subtraction angiography.
Br J Radiol. 1989 Sep;62(741):838-42. doi: 10.1259/0007-1285-62-741-838.
5
Ocular lens dose in cerebral vascular imaging.
Br J Radiol. 1988 Mar;61(723):202-4. doi: 10.1259/0007-1285-61-723-202.
9
Radiation exposure in perfusion CT of the brain.脑部灌注CT中的辐射暴露。
J Comput Assist Tomogr. 2014 Jan-Feb;38(1):25-8. doi: 10.1097/RCT.0b013e3182a3f9a0.