Suppr超能文献

办公室职员中的空气过敏原与工作相关的呼吸道症状

Aeroallergens and work-related respiratory symptoms among office workers.

作者信息

Menzies D, Comtois P, Pasztor J, Nunes F, Hanley J A

机构信息

Department of Epidemiology and Biostatistics, McGill University, Montreal, Quebec, Canada.

出版信息

J Allergy Clin Immunol. 1998 Jan;101(1 Pt 1):38-44. doi: 10.1016/S0091-6749(98)70191-5.

Abstract

OBJECTIVE

We sought to determine the association between office workers' respiratory tract symptoms and immediate skin test reactions with exposure to fungal and house dust mite aeroallergens at their work sites.

METHODS

An initial prevalence survey was conducted among 1102 full-time workers in six mechanically ventilated, air-conditioned, nonindustrial buildings in downtown Montreal. Detailed environmental measures of 214 subjects' work sites were determined. Half of the workers reported frequent work-related respiratory tract symptoms on the initial survey. Participants simultaneously underwent allergy skin prick testing and completed a second self-administered questionnaire.

RESULTS

Contaminant levels were low and not associated with symptoms in the great majority of workers. For approximately 17% of workers, symptoms were associated with exposure to total concentrations of house dust mite allergen greater than 1 microg/gm floor dust (odds ratio [OR], 5.0; 95% confidence interval [CI], 1.3, 19.5]) or to detectable airborne Alternaria allergens in their offices (OR, 3.3; 95% CI, 1.2, 9.4 and in the ventilation system supplying their offices (OR, 3.9; 95% CI, 1.6, 9.6). Workers with positive skin test reactions to Alternaria extract were exposed at their work site to airborne Alternaria allergen (OR, 4.4; 95% CI, 1.4, 14.5) and cited significantly more respiratory symptoms on both questionnaires. Detection of airborne Alternaria allergen at work sites was significantly associated with detection in the ventilation system (OR, 4.0; 95% CI, 1.4,10.9); this was in turn associated with lower efficiency filters.

CONCLUSIONS

Potentially avoidable exposure to aeroallergens accounted for symptoms in a small subgroup of office workers with frequent work-related respiratory tract symptoms.

摘要

目的

我们试图确定办公室工作人员的呼吸道症状与在工作场所接触真菌和屋尘螨气传变应原时立即出现的皮肤试验反应之间的关联。

方法

对蒙特利尔市中心六座采用机械通风、空调且非工业建筑中的1102名全职工作人员进行了初步患病率调查。确定了214名受试者工作场所的详细环境指标。在初步调查中,一半的工作人员报告有频繁的与工作相关的呼吸道症状。参与者同时接受了过敏皮肤点刺试验,并完成了第二份自行填写的问卷。

结果

在绝大多数工作人员中,污染物水平较低且与症状无关。对于约17%的工作人员,症状与接触屋尘螨变应原总浓度大于1微克/克地板灰尘有关(优势比[OR],5.0;95%置信区间[CI],1.3,19.5),或与办公室中可检测到的链格孢属变应原有关(OR,3.3;95%CI,1.2,9.4),以及与为其办公室提供通风的系统中可检测到的链格孢属变应原有关(OR,3.9;95%CI,1.6,9.6)。对链格孢属提取物皮肤试验反应呈阳性的工作人员在其工作场所接触到了空气中的链格孢属变应原(OR,4.4;95%CI,1.4,14.5),并且在两份问卷中提及的呼吸道症状明显更多。工作场所空气中链格孢属变应原的检测与通风系统中的检测显著相关(OR,4.0;95%CI,1.4,10.9);这反过来又与效率较低的过滤器有关。

结论

在一小部分有频繁工作相关呼吸道症状的办公室工作人员中,潜在可避免的气传变应原暴露导致了症状的出现。