Suppr超能文献

角膜应力测试——通过隐形眼镜诱导应力对体内角膜内皮功能的评估。

Cornea stress test--evaluation of corneal endothelial function in vivo by contact lens induced stress.

作者信息

Saini J S, Mittal S, Anand M

机构信息

Dept. of Ophthalmology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.

出版信息

Indian J Ophthalmol. 1997 Mar;45(1):19-24.

PMID:9475007
Abstract

Reliable and valid assessment of corneal endothelial function is a critical input for diagnosing, prognosticating and monitoring progression of disorders affecting corneal endothelium. In 123 eyes, corneal endothelial function was assessed employing data from the corneal hydration recovery dynamics. Serial pachometric readings were recorded on Haag-Striet pachometer with Mishima-Hedbys modification before and after two hours of thick soft contact lens wear. Percentage Recovery Per Hour (PRPH) was derived from raw data as an index of endothelial function. Assessed PRPH in pseudophakic corneal oedema and Fuchs' endothelial dystrophy eyes (35.9 +/- 9.8%) was significantly lower than normal controls (61.9 +/- 10.5%). On employing receiver operation characteristics curve analysis the tested results demonstrated high sensitivity (87%) and specificity (92%) for detection of low endothelial function at PRPH cut off of 47.5%. Using this PRPH cut off, 80% of Fuchs' endothelial dystrophy and 93.3% of pseudophakic corneal oedema eyes could be demonstrated to have low endothelial function. A total of 66.7% of diabetic eyes also demonstrated PRPH of lower than 47.5%. Clear corneal grafts demonstrated PRPH values of 24.6% to 73.0%. Of 6 corneal grafts that demonstrated initial PRPH of lower than 47.5%, 4 failed within 4 to 6 months. Our data demonstrated high sensitivity and specificity of this corneal stress test. PRPH index was useful in quantifying endothelial function in clinical disorders including diabetes mellitus. The index PRPH was demonstrated to be useful in monitoring and prognosticating outcome of corneal grafts.

摘要

对角膜内皮功能进行可靠且有效的评估是诊断、预测和监测影响角膜内皮疾病进展的关键依据。在123只眼中,利用角膜水化恢复动力学数据评估角膜内皮功能。在佩戴厚软性隐形眼镜两小时前后,使用经三岛-赫德比斯改良的 Haag-Striet 角膜厚度仪记录系列角膜厚度测量值。每小时恢复百分比(PRPH)由原始数据得出,作为内皮功能指标。人工晶状体眼合并角膜水肿和富克斯内皮营养不良眼的评估PRPH(35.9±9.8%)显著低于正常对照组(61.9±10.5%)。通过受试者工作特征曲线分析,测试结果表明,在PRPH临界值为47.5%时,检测低内皮功能具有高敏感性(87%)和特异性(92%)。使用该PRPH临界值,80%的富克斯内皮营养不良眼和93.3%的人工晶状体眼合并角膜水肿眼可被证明具有低内皮功能。总共66.7%的糖尿病眼PRPH也低于47.5%。透明角膜移植片的PRPH值为24.6%至73.0%。在6只初始PRPH低于47.5%的角膜移植片中,有4只在4至6个月内失败。我们的数据表明该角膜应激试验具有高敏感性和特异性。PRPH指数有助于量化包括糖尿病在内的临床疾病中的内皮功能。PRPH指数被证明有助于监测和预测角膜移植的结果。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验