Thermal properties of capacitively coupled electrodes in interstitial hyperthermia.

作者信息

van der Koijk J F, Crezee J, Lagendijk J J

机构信息

University Hospital Utrecht, Department of Radiotherapy, The Netherlands.

出版信息

Phys Med Biol. 1998 Jan;43(1):139-53. doi: 10.1088/0031-9155/43/1/009.

DOI:10.1088/0031-9155/43/1/009
PMID:9483628
Abstract

The multi-electrode current source (MECS) interstitial hyperthermia system which is used for treatment of cancer, employs segmented electrodes inserted in plastic tubes implanted in the treatment volume. The mean power deposition of the individual electrodes is controlled by varying the duty cycle of the RF signal applied to the electrodes, using thermocouples inside the electrodes for thermometry. A non-zero loss angle results in self-heating of the catheter. The thermal influence of self-heating was investigated and an analysis of the measurement of temperatures inside the catheter during and after heating is presented. Analytical models and a high-resolution numerical model were used for the calculation of steady state and transient distributions, respectively. The model results are compared with experimental data obtained in a muscle equivalent phantom. Results indicate that there is no difference between temperature inside and outside the catheter when using lossless catheter materials (e.g. PE and PTFE). Self-heating in the catheter wall has an adverse effect on the uniformity of the stationary temperature distribution and the reliability of temperature measurement with internal thermometry. These problems remain within acceptable limits for mildly lossy materials; the difference between the temperature inside and outside is only 6% when using low-loss Nylon. Analysis of the thermal decay after power-off shows that low-loss materials allow more time to obtain an accurate estimate of the tissue temperature at the catheter wall during power-on. This effect is enhanced by the presence of minute air layers in the applicator. Distortion of temperature gradients along the catheter was also investigated. Key factors are the thermal conduction across the catheter wall, and especially the presence of minute layers of air between consecutive layers of the probe. The distortion extends less than two millimetres, which is acceptable. The simulation results are compatible with measurements in phantoms and show that, if the proper choice of materials is made, the MECS applicator answers our expectations and that the temperature measurement inside the catheter can be used for direct feedback treatment control.

摘要

相似文献

1
Thermal properties of capacitively coupled electrodes in interstitial hyperthermia.
Phys Med Biol. 1998 Jan;43(1):139-53. doi: 10.1088/0031-9155/43/1/009.
2
Temperature measurement errors with thermocouples inside 27 MHz current source interstitial hyperthermia applicators.
Phys Med Biol. 1999 Jun;44(6):1499-511. doi: 10.1088/0031-9155/44/6/305.
3
Implications of using thermocouple thermometry in 27 MHz capacitively coupled interstitial hyperthermia.27兆赫兹电容耦合组织间热疗中使用热电偶测温法的意义
Phys Med Biol. 1997 Apr;42(4):637-50. doi: 10.1088/0031-9155/42/4/003.
4
Numerical analysis of capacitively coupled electrodes for interstitial hyperthermia.
Int J Hyperthermia. 1997 Nov-Dec;13(6):607-19. doi: 10.3109/02656739709023560.
5
Clinical thermometry, using the 27 MHz multi-electrode current-source interstitial hyperthermia system in brain tumours.
Radiother Oncol. 2001 May;59(2):227-31. doi: 10.1016/s0167-8140(01)00310-3.
6
Spatial temperature control with a 27 MHz current source interstitial hyperthermia system.
Int J Radiat Oncol Biol Phys. 1997 Jan 1;37(1):189-97. doi: 10.1016/s0360-3016(96)00476-2.
7
Design of applicators for a 27 MHz multielectrode current source interstitial hyperthermia system; impedance matching and effective power.用于27MHz多电极电流源间质热疗系统的施药器设计;阻抗匹配与有效功率。
Phys Med Biol. 1997 Jun;42(6):1087-108. doi: 10.1088/0031-9155/42/6/007.
8
Dose uniformity in MECS interstitial hyperthermia: the impact of longitudinal control in model anatomies.微波等效电流源间质热疗中的剂量均匀性:模型解剖结构中纵向控制的影响
Phys Med Biol. 1996 Mar;41(3):429-44. doi: 10.1088/0031-9155/41/3/007.
9
Spatial steering with quadruple electrodes in 27 MHz capacitively coupled interstitial hyperthermia.
Int J Hyperthermia. 1999 Mar-Apr;15(2):145-56. doi: 10.1080/026567399285792.
10
A feasibility study of interstitial hyperthermia plus external beam radiotherapy in glioblastoma multiforme using the Multi ELectrode Current Source (MECS) system.使用多电极电流源(MECS)系统对多形性胶质母细胞瘤进行间质热疗联合外照射放疗的可行性研究。
Int J Hyperthermia. 2004 Aug;20(5):451-63. doi: 10.1080/02656730410001668357.