• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[CarboMedics“礼帽”超环瓣假体用于严重钙化的小主动脉根部:一例报告]

[CarboMedics "Top Hat" supraannular prosthesis in the small aortic root with severe calcification: a case report].

作者信息

Toyoda Y, Shida T, Wakita N, Ozaki N

机构信息

Kobe Rhousai Hospital, Japan.

出版信息

Kyobu Geka. 1998 Feb;51(2):135-7.

PMID:9492464
Abstract

A 71-year-old man with aortic stenosis due to calcification successfully underwent aortic valve replacement with a 21-mm CarboMedics "Top Hat" supraannular prosthesis. We were able to implant a "Top Hat" valve one size larger than would have been possible using a standard bileaflet valve. The postoperative recovery was uneventful, and echocardiography showed a peak gradient of 23 mmHg for this prosthesis. The CarboMedics supraannular valve allowed a gain in size over standard prostheses, resulting in favorable hemodynamics. This valve may be useful in difficult or unsuitable cases to enlarge the narrow aortic valve ring, such as patients with severe calcification of aortic root, elderly patients with less activity, or patients who can tolerate only short cardiopulmonary bypass time due to cardiac dysfunction.

摘要

一名71岁因钙化导致主动脉瓣狭窄的男性成功接受了主动脉瓣置换术,使用的是21毫米CarboMedics“顶帽”瓣环上假体。我们能够植入比使用标准双叶瓣大一号的“顶帽”瓣。术后恢复顺利,超声心动图显示该假体的峰值梯度为23 mmHg。CarboMedics瓣环上瓣膜比标准假体尺寸更大,从而产生了良好的血流动力学。这种瓣膜在困难或不合适的病例中可能有用,例如主动脉根部严重钙化的患者、活动较少的老年患者或因心脏功能障碍只能耐受短时间体外循环的患者,可用于扩大狭窄的主动脉瓣环。

相似文献

1
[CarboMedics "Top Hat" supraannular prosthesis in the small aortic root with severe calcification: a case report].[CarboMedics“礼帽”超环瓣假体用于严重钙化的小主动脉根部:一例报告]
Kyobu Geka. 1998 Feb;51(2):135-7.
2
Performance at 10 years of the CarboMedics "Top-Hat" valve. Postclamping time is a predictor of mortality.
Eur J Cardiothorac Surg. 2006 Feb;29(2):144-9. doi: 10.1016/j.ejcts.2005.10.044. Epub 2005 Dec 20.
3
Midterm evaluation of hemodynamics of the Top Hat supraannular aortic valve.
Asian Cardiovasc Thorac Ann. 2010 Feb;18(1):54-8. doi: 10.1177/0218492309355720.
4
Doppler-echocardiographic assessment of the carbomedics supra-annular 'Top-Hat' prosthetic heart valve in the aortic position.
J Heart Valve Dis. 1996 Nov;5 Suppl 3:S336-8.
5
Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve.
J Heart Valve Dis. 2007 Jan;16(1):84-90.
6
The CarboMedics "Top-Hat" supraannular prosthesis.
Ann Thorac Surg. 1999 May;67(5):1299-303. doi: 10.1016/s0003-4975(99)00170-8.
7
A randomized comparison of the MCRI On-X and CarboMedics Top Hat bileaflet mechanical replacement aortic valves: early postoperative hemodynamic function and clinical events.MCRI On-X与CarboMedics Top Hat双叶机械置换主动脉瓣的随机对照研究:术后早期血流动力学功能及临床事件
J Thorac Cardiovasc Surg. 2005 Sep;130(3):759-64. doi: 10.1016/j.jtcvs.2005.02.057.
8
[Endarterectomy and aortic valve replacement in a patient with severely calcified ascending aortic root].[严重钙化升主动脉根部患者的内膜切除术和主动脉瓣置换术]
Kyobu Geka. 2009 Dec;62(13):1132-5.
9
[Translocation of the aortic valve for aortic stenosis in a patient with severe calcification in the aortic root: report of a case].[主动脉根部严重钙化患者主动脉瓣置换术治疗主动脉瓣狭窄:病例报告]
Kyobu Geka. 2001 Jul;54(8 Suppl):719-21.
10
The CarboMedics supra-annular Top Hat valve improves long-term left ventricular mass regression.卡波美迪克斯超环顶帽瓣膜可改善左心室质量的长期消退。
J Thorac Cardiovasc Surg. 2014 Dec;148(6):2845-53.e1. doi: 10.1016/j.jtcvs.2014.06.082. Epub 2014 Jul 23.