Metwally W A, Habib A N, Katamish H A
Corrosion Dept., Central Metallurgical Research and Development Institute, Helwan, Cairo, Egypt.
Egypt Dent J. 1995 Apr;41(2):1159-66.
In order to evaluate the corrosion behaviour of some dental alloys to be applied as base-metal for PFM, electrochemical technique and metallurgical investigation were used. Potentiodynamic and potentiostatic tests were carried out under deaerated and aerated conditions in 1% NaCl solution. The results have shown that Ni-Cr alloy has a superior corrosion resistance under deaerated conditions, whereas Co-Cr alloy has a stronger tendency to passivation under aerated conditions. Fe-Cr alloy has demonstrated a poor performance. The results were analyzed on compositional and microstructural bases.