Mannino G, De Bella F, Bozzoni Pantaleoni F, Pescosolido N, Balacco Gabrieli C
University of Rome La Sapienza, Institute of Ophthalmology, Italy.
Ophthalmic Surg Lasers. 1998 Feb;29(2):157-61.
High-frequency ultrasound biomicroscopy (UBM) has extensive powers of resolution. This makes it possible to explore and study some areas of the anterior segment with a clarity close to that of histologic preparations. High-frequency UBM was used in the clinical evaluation of 10 glaucomatous eyes subjected to ab externo holmium:yttrium-aluminum-garnet (Ho:YAG) laser sclerostomy. The anatomic characteristics of the fistular paths were viewed and compared with echographic images. The authors demonstrated that in the 5 cases where the filtering bleb, fistular path, and internal ostium were present, there was a reduction of intraocular pressure. UBM is a high-definition diagnostic instrument in the follow-up of fistular paths and filtering blebs after Ho:YAG laser sclerostomy, making it possible to reoperate at an early stage before the onset of clinical manifestations.
高频超声生物显微镜检查(UBM)具有强大的分辨率。这使得能够以前所未有的清晰度探索和研究眼前节的一些区域,其清晰度接近组织学标本。高频UBM用于对10只接受外路钬:钇铝石榴石(Ho:YAG)激光巩膜造瘘术的青光眼患眼进行临床评估。观察瘘管路径的解剖特征并与超声图像进行比较。作者证明,在存在滤过泡、瘘管路径和内口的5例病例中,眼压有所降低。UBM是Ho:YAG激光巩膜造瘘术后瘘管路径和滤过泡随访中的一种高清诊断仪器,使得在临床表现出现之前的早期阶段就可以再次手术。