Budak K, Friedman N J, Koch D D
Cullen Eye Institute, Baylor College of Medicine, Department of Ophthalmology, Houston, Texas 77030, USA.
J Cataract Refract Surg. 1998 Feb;24(2):278-80. doi: 10.1016/s0886-3350(98)80211-3.
We report a case of dehiscence of a radial keratotomy (RK) incision caused by clear corneal cataract surgery. The patient had eight-incision RK in both eyes 9 months previously with enhancement surgery in the left eye 1 month later. Cataract surgery through a clear corneal incision was performed in the right eye and 1 month later, in the left. Surgery in the right eye was uneventful. However, during surgery in the left eye, dehiscence of one radial incision occurred. The wound dehiscence was closed with interrupted sutures, and the patient achieved 20/20, uncorrected visual acuity 1 week after surgery.
我们报告了一例因透明角膜白内障手术导致的放射状角膜切开术(RK)切口裂开的病例。该患者9个月前双眼行八切口RK手术,1个月后左眼行增效手术。右眼经透明角膜切口进行白内障手术,1个月后左眼进行手术。右眼手术顺利。然而,在左眼手术过程中,一个放射状切口发生裂开。伤口裂开用间断缝线缝合,术后1周患者获得了20/20的未矫正视力。