用于检测缺血性心脏病的201铊和99锝-替曲膦双同位素采集比较及99锝-替曲膦最佳成像时间的确定

Comparison of dual-isotope acquisition of 201Tl and 99Tcm-tetrofosmin for the detection of ischaemic heart disease and determination of the optimal imaging time of 99Tcm-tetrofosmin.

作者信息

Ito Y, Uehara T, Fukuchi K, Tsujimura E, Hasegawa S, Nishimura T

机构信息

Division of Tracer Kinetics, Biomedical Research Centre, Osaka University Medical School, Suita, Japan.

出版信息

Nucl Med Commun. 1998 Feb;19(2):119-26. doi: 10.1097/00006231-199802000-00005.

Abstract

Comparative studies of thallium-201 (201Tl) and 99Tcm-tetrofosmin for the detection of ischaemic heart disease (IHD) have previously been reported. These 201Tl and 99Tcm-tetrofosmin studies were usually performed separately with different exercise loads at an interval of several days. Here, we used a dual-isotope technique with exercise myocardial SPET (single photon emission tomography) in 17 patients with IHD and 10 patients with normal coronary arteries. The triple-energy window (TEW) method was applied for cross-talk correction. SPET imaging was performed at 10 and 70 min (S1 and S2) after the injection of 99Tcm-tetrofosmin (222 MBq) and 201Tl (74 MBq) at peak exercise to determine the optimal imaging time of 99Tcm-tetrofosmin. The S2 value was obtained 35 min after the subject drank a glass of milk to accelerate hepatobiliary clearance. Twenty-five minutes after S2, 37 MBq of 201Tl were reinjected at rest and SPET imaging (S3) was performed. Immediately after S3, 666 MBq of 99Tcm-tetrofosmin were reinjected and SPET imaging (S4) was performed 50 min later. Representative short and vertical long axis tomograms were divided into 17 segments. Each segment was assessed using a 4-point scoring system. The defect score was defined as the sum of each segmental score. The defect scores for imaging at exercise were 14.3 +/- 11.4 for 201Tl at S1, 11.4 +/- 8 for 99Tcm-tetrofosmin at S1 and 9.7 +/-9.8 for 99Tcm-tetrofosmin at S2 (P < 0.01), respectively. The washout rate of 99Tcm-tetrofosmin for the first hour was 15.5 +/- 7.3% and 11.8 +/- 7.7% (P < 0.01), respectively, for the normal and ischaemic segments. The image quality of 201Tl at S1 was almost equivalent to that of 99Tcm-tetrofosmin at S1/S2. The overall sensitivity and specificity for the detection of ischaemia was 94% and 82% for 201Tl at S1, 89% and 86% for 99Tcm-tetrofosmin at S1, and 88% and 95% for 99Tcm-tetrofosmin at S2, respectively. The overall accuracy was 86%, 88% and 92%, respectively. The myocardial viability score was 7.4 +/- 7.1 for 201Tl at S3 and 5.8 +/- 7.0 for 99Tcm-tetrofosmin at S4 (P < 0.01). The results indicate that the diagnostic accuracy of 99Tcm-tetrofosmin for myocardial ischaemia is almost equivalent to that of 201Tl as assessed by dual SPET imaging, and that the optimal imaging time for 99Tcm-tetrofosmin is within 10-35 min (S1) after exercise.

摘要

先前已有关于铊 - 201(²⁰¹Tl)和锝 - 99m - 替曲膦用于检测缺血性心脏病(IHD)的比较研究报道。这些²⁰¹Tl和锝 - 99m - 替曲膦研究通常是分别进行的,采用不同的运动负荷,且间隔数天。在此,我们对17例缺血性心脏病患者和10例冠状动脉正常的患者采用双同位素技术结合运动心肌单光子发射断层扫描(SPET)。应用三能量窗(TEW)方法进行串扰校正。在运动高峰时注射锝 - 99m - 替曲膦(222 MBq)和²⁰¹Tl(74 MBq)后10分钟和70分钟(S1和S2)进行SPET成像,以确定锝 - 99m - 替曲膦的最佳成像时间。受试者饮用一杯牛奶以加速肝胆清除后35分钟获得S2值。S2后25分钟,静息状态下再次注射37 MBq的²⁰¹Tl并进行SPET成像(S³)。S3后立即再次注射666 MBq的锝 - 99m - 替曲膦,并在50分钟后进行SPET成像(S4)。代表性的短轴和垂直长轴断层图像被分为17个节段。每个节段采用4分评分系统进行评估。缺损分数定义为各节段分数之和。运动时成像的缺损分数,S1时²⁰¹Tl为14.3±11.4,S1时锝 - 99m - 替曲膦为11.4±8,S2时锝 - 99m - 替曲膦为9.7±9.8(P<0.01)。正常节段和缺血节段锝 - 99m - 替曲膦第一小时的洗脱率分别为15.5±⁷.³%和11.8±⁷.⁷%(P<0.01)。S1时²⁰¹Tl的图像质量与S1/S2时锝 - 99m - 替曲膦的图像质量几乎相当。S1时²⁰¹Tl检测缺血的总体敏感性和特异性分别为94%和82%,S1时锝 - 99m - 替曲膦为89%和86%,S2时锝 - 99m - 替曲膦为88%和95%。总体准确性分别为86%、8⁸%和92%。S3时²⁰¹Tl的心肌存活分数为7.4±7.1,S4时锝 - 99m - 替曲膦为5.8±7.0(P<0.01)。结果表明,通过双SPET成像评估,锝 - 99m - 替曲膦对心肌缺血的诊断准确性与²⁰¹Tl几乎相当,且锝 - 99m - 替曲膦的最佳成像时间在运动后10 - 35分钟(S1)内。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验