The aim of this study was to determine the utility of 99Tcm-tetrofosmin cardiac imaging in patients with previous myocardial infarction and with significant coronary artery disease (CAD) compared with that of 201Tl cardiac imaging. Sixteen patients (14 males, 2 females) were studied by same-day exercise-rest 99Tcm-tetrofosmin imaging and exercise, rest and reinjection 201Tl cardiac imaging. For each study, semi-quantitative visual analysis was performed in 20 segments using a 4-point scale. The regional distribution and defect reversibility with the two tracers were compared with the results of coronary angiography. A total of 320 segments were analysed. There was a statistically significant concordance between the numbers of fixed and reversible segments in both studies in myocardial segments supplied by totally occluded coronary arteries (Group 1), as well as in segments supplied by significantly stenosed coronary vessels (Group 2). The exercise and rest uptake of both 99Tcm-tetrofosmin and 201Tl in myocardial segments supplied by totally occluded coronary arteries with poor collateral flow was significantly lower compared with segments supplied by totally occluded coronary arteries with efficient collateral flow (P < or = 0.05). When the uptake of both tracers was analysed according to each major vascular territory, the mean exercise and rest uptake grades of 99Tcm-tetrofosmin and 201Tl were similar. There was also no significant difference in defect reversibility between the two tracers. Discordant results were observed in the territory of the right coronary artery in Group 1 (mean exercise grade of 99Tcm-tetrofosmin = 2.26 +/- 0.7 and of 201Tl = 1.92 +/- 0.8; P < or = 0.001) and in Group 2 (mean grade of 99Tcm-tetrofosmin = 0.79 +/- 0.65 and of 201Tl = 0.95 +/- 0.65; P < or = 0.05). The results of the present study indicate that the overall diagnostic utility of 99Tcm-tetrofosmin in the identification of individual stenosed vessels is comparable with 201Tl in both patients with totally occluded coronary arteries and those with significantly stenosed vessels. The regional distribution of both tracers was lower in myocardial segments supplied by totally occluded coronary arteries with poor collateral flow.

摘要

本研究的目的是确定与201Tl心肌显像相比,99Tcm - 替曲膦心肌显像在既往有心肌梗死且患有严重冠状动脉疾病(CAD)患者中的应用价值。对16例患者(14例男性,2例女性)进行了同日运动 - 静息99Tcm - 替曲膦显像以及运动、静息和再注射201Tl心肌显像研究。对于每项研究,使用4分制在20个节段进行半定量视觉分析。将两种示踪剂的区域分布和缺损可逆性与冠状动脉造影结果进行比较。共分析了320个节段。在完全闭塞冠状动脉供血的心肌节段(第1组)以及严重狭窄冠状动脉供血的节段(第2组)中,两项研究中固定节段和可逆节段的数量之间存在统计学上的显著一致性。与有有效侧支循环供血的完全闭塞冠状动脉供血的节段相比,侧支循环不良的完全闭塞冠状动脉供血的心肌节段中,99Tcm - 替曲膦和201Tl的运动和静息摄取均显著降低(P≤0.05)。当根据每个主要血管区域分析两种示踪剂的摄取情况时,99Tcm - 替曲膦和201Tl的平均运动和静息摄取等级相似。两种示踪剂在缺损可逆性方面也无显著差异。在第1组右冠状动脉区域(99Tcm - 替曲膦平均运动等级 = 2.26±0.7,201Tl平均运动等级 = 1.92±0.8;P≤0.001)和第2组(99Tcm - 替曲膦平均等级 = 0.79±0.65,201Tl平均等级 = 0.95±0.65;P≤0.05)观察到不一致的结果。本研究结果表明,在识别单个狭窄血管方面,99Tcm - 替曲膦的总体诊断效用在完全闭塞冠状动脉的患者和严重狭窄血管的患者中与201Tl相当。在侧支循环不良的完全闭塞冠状动脉供血的心肌节段中,两种示踪剂的区域分布均较低。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验