血小板在CP2D中储存后血浆体积的减少。

Reduction of plasma volume after storage of platelets in CP2D.

作者信息

Rock G, Haddad S A, Poon A O, Romans R A, Sparling C R, St Louis P, Berger R

机构信息

Ottawa Civic Hospital, and the Department of Laboratory Medicine, University of Ottawa, Ontario, Canada.

出版信息

Transfusion. 1998 Mar;38(3):242-6. doi: 10.1046/j.1537-2995.1998.38398222867.x.

Abstract

BACKGROUND

There has been concern that further deterioration might occur if stored platelets are centrifuged to reduce their volume. Although such centrifugation appears to have minimal effect on platelets in CPDA-1 (osmolarity, 470 mOsm) there is no information on the situation with CP2D (580 mOsm).

STUDY DESIGN AND METHODS

Platelet concentrates from CP2D packs were sampled at 1 and 5 days and after centrifugation was used to reduce the plasma volume to 10 mL. The aggregation, hypotonic shock response, morphology, pH, and lactate, glucose, pCO2 and pO2 levels were assessed, and values were compared to those seen with CPDA-1. In addition, blood was collected from the same donors into both CP2D and standard sodium citrate anticoagulant in an anticoagulant-to-blood ratio of 1:8 and the aggregation response of the fresh platelets was measured.

RESULTS

Collection of blood into CP2D results in an immediate reduction of the platelet aggregation response when compared to that found after collection of blood into sodium citrate or CPDA-1. Aggregation is further decreased after storage; however, these changes and those for hypotonic shock, pH, lactate, glucose, and pCO2 are similar to those seen for CPDA-1. Additional centrifugation did not cause further change.

CONCLUSION

Platelets stored in CP2D have reduced in vitro function after 5 days of storage, but subsequent centrifugation to reduce the plasma volume does not further alter these platelets.

摘要

背景

一直有人担心,如果对储存的血小板进行离心以减少其体积,可能会导致其进一步恶化。尽管这种离心似乎对CPDA-1(渗透压470 mOsm)中的血小板影响极小,但关于CP2D(580 mOsm)情况的信息却没有。

研究设计与方法

从CP2D血袋中采集血小板浓缩物,分别在储存1天和5天时进行采样,然后进行离心,将血浆体积减少至10 mL。评估其聚集性、低渗休克反应、形态、pH值以及乳酸、葡萄糖、pCO2和pO2水平,并将这些值与CPDA-1中的情况进行比较。此外,从相同供体采集血液,分别加入CP2D和标准枸橼酸钠抗凝剂,抗凝剂与血液的比例为1:8,测量新鲜血小板的聚集反应。

结果

与采集到枸橼酸钠或CPDA-1中的血液相比,采集到CP2D中的血液会立即降低血小板聚集反应。储存后聚集性进一步降低;然而,这些变化以及低渗休克、pH值、乳酸、葡萄糖和pCO2的变化与CPDA-1中的情况相似。额外的离心并未导致进一步变化。

结论

储存在CP2D中的血小板在储存5天后体外功能降低,但随后为减少血浆体积而进行的离心不会进一步改变这些血小板。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验