全膝关节置换术后系列X线片的价值。

The value of serial postoperative radiographs of total knee arthroplasties.

作者信息

Thomason H C, Slater R R, Tooma G S, Rosu M R, Kelley S S

机构信息

Department of Statistics, University of North Carolina at Chapel Hill, 27599-7055, USA.

出版信息

J South Orthop Assoc. 1998 Spring;7(1):27-35.

PMID:9570729
Abstract

In a prospective study of 35 cemented press fit condylar knees, we studied the prevalence of radiolucent lines 1 mm wide or wider using two methods of detection: conventional (plain) and fluoroscopically-guided radiographs. All films were evaluated in accordance with the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. A total of 12 radiolucencies were detected in nine knees (26% of all knees) using conventional radiographs versus 25 radiolucencies in 13 knees (37% of all knees) using fluoroscopically-guided radiographs. This was a statistically significant difference and suggests that the true prevalence of periprosthetic radiolucencies will be underestimated if conventional radiographs are used to evaluate the bone-prosthesis interfaces and questions the value of routine postoperative plain film radiographs to evaluate the results of knee arthroplasty.

摘要

在一项对35例骨水泥固定压配型髁膝关节的前瞻性研究中,我们使用两种检测方法研究了宽度为1毫米或更宽的透光线的发生率:传统(普通)X线片和透视引导下的X线片。所有胶片均按照膝关节协会全膝关节置换术X线评估和评分系统进行评估。使用传统X线片在9个膝关节中检测到总共12处透光线(占所有膝关节的26%),而使用透视引导下的X线片在13个膝关节中检测到25处透光线(占所有膝关节的37%)。这是一个具有统计学意义的差异,表明如果使用传统X线片评估骨-假体界面,假体周围透光线的真实发生率将被低估,这也对常规术后普通X线片评估膝关节置换术结果的价值提出了质疑。