Lee H M, Wang Y, Sostman H D, Schwartz L H, Khilnani N M, Trost D W, Ramirez de Arellano E, Teeger S, Bush H L
Department of Radiology, Cornell University Medical College, New York, NY 10021, USA.
Radiology. 1998 May;207(2):505-12. doi: 10.1148/radiology.207.2.9577502.
To test the hypothesis that magnetic resonance (MR) digital subtraction angiography is superior to two-dimensional time-of-flight (TOF) MR angiography for demonstration of patent arteries in the distal lower extremity.
Thirty-seven lower extremities in 23 consecutive patients were imaged with two-dimensional TOF MR angiography and two-dimensional MR digital subtraction angiography. Images were interpreted in a randomized and blinded manner. Each lower extremity was subdivided into seven potential arterial segments. The number of digital arteries visualized was also determined. Overall image quality of MR digital subtraction and TOF angiograms was compared. The relative ability of MR digital subtraction angiography and TOF MR angiography to demonstrate patent arterial segments was assessed.
MR digital subtraction angiography was significantly superior to TOF MR angiography for demonstration of patent arterial segments and digital arteries (P < .001). MR digital subtraction angiographic images were qualitatively superior to TOF images (P < .001).
Two-dimensional MR digital subtraction angiography is superior to two-dimensional TOF MR angiography for help in identifying patent segments in the distal lower extremity.
验证磁共振(MR)数字减影血管造影术在显示下肢远端动脉通畅情况方面优于二维时间飞跃(TOF)MR血管造影术这一假设。
对连续23例患者的37条下肢进行二维TOF MR血管造影术和二维MR数字减影血管造影术成像。图像以随机且盲法方式解读。每个下肢被细分为七个潜在动脉节段。还确定了可见指动脉的数量。比较了MR数字减影和TOF血管造影的总体图像质量。评估了MR数字减影血管造影术和TOF MR血管造影术显示动脉节段通畅的相对能力。
在显示动脉节段通畅和指动脉方面,MR数字减影血管造影术明显优于TOF MR血管造影术(P < .001)。MR数字减影血管造影图像在质量上优于TOF图像(P < .001)。
二维MR数字减影血管造影术在帮助识别下肢远端通畅节段方面优于二维TOF MR血管造影术。