Role of transesophageal echocardiography in the diagnosis of infected retained pacing lead.

作者信息

Barbetseas J, Lalos S, Kyriakidis M, Aggeli C, Toutouzas P

机构信息

Department of Cardiology, Athens University School of Medicine, Greece.

出版信息

Pacing Clin Electrophysiol. 1998 May;21(5):1159-61. doi: 10.1111/j.1540-8159.1998.tb00165.x.

Abstract

A 68-year-old woman had a transvenous pacemaker implanted 6 years ago. One year after the procedure the pulse generator was removed due to generator site infection. Efforts to remove the lead resulted in fracture of the tip, which was abandoned in the right cardiac cavities. After this the patient suffered intermittent episodes of fever and chills, which responded to antibiotic therapy. At her recent admission, transesophageal echocardiography revealed a large mass attached to the free end of the fractured lead suggestive of the existence of a vegetation on the pacing lead. The diagnosis was confirmed at surgery.

摘要

一名68岁女性6年前植入了经静脉起搏器。术后1年,因发生器部位感染取出了脉冲发生器。试图取出导线时导致尖端断裂,于是将断裂的尖端留在了右心腔内。此后,患者反复出现发热和寒战,抗生素治疗有效。在她最近一次入院时,经食管超声心动图显示在断裂导线的游离端附着有一个大肿块,提示起搏导线上存在赘生物。手术确诊了这一诊断。