Buchanan J W, Sammarco C D
Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, Philadelphia 19104, USA.
Vet Surg. 1998 May-Jun;27(3):182-93. doi: 10.1111/j.1532-950x.1998.tb00117.x.
To develop a method for reducing mitral regurgitation in dogs by positioning and tightening a circumferential suture around the mitral valve annulus.
Description of clinical cases.
15 dogs with spontaneous mitral valve disease, annular dilation, and refractory congestive heart failure treated between 1962 and 1994.
A composite suture material was constructed using braided Teflon-impregnated polyester sternotomy suture, barium sulfate thread, and Silastic tubing. Through a left lateral thoracotomy, the suture was positioned around the mitral annulus by passing it through the coronary sinus, right atrium, and underneath the left coronary arteries before tightening it.
Six dogs died during surgery because of hemorrhage from the left atrium, coronary sinus, or left coronary artery. Three dogs died postoperatively because of coronary artery compression by the suture. Satisfactory suture placement was achieved in six dogs, three of which were long-term survivors (6 to 26 months) before they were euthanatized for noncardiac reasons.
Reduction of mitral annulus diameter with a circumferential purse-string suture does not require cardiopulmonary bypass. The surgery is technically difficult, and detailed knowledge of coronary artery anatomy is required. The current suture design is inexpensive, radiopaque, and biocompatible; no special instruments are required for placement.
Mitral regurgitation is the most common cardiovascular disorder in dogs and the most common cause of congestive heart failure. Annular dilation occurs as a consequence of mitral regurgitation. Placement and tightening of a circumferential suture around the mitral annulus reduces the degree of mitral regurgitation.
通过在二尖瓣环周围定位并收紧环形缝线,开发一种减少犬二尖瓣反流的方法。
临床病例描述。
1962年至1994年间治疗的15只患有自发性二尖瓣疾病、瓣环扩张和难治性充血性心力衰竭的犬。
使用编织的含聚四氟乙烯的聚酯胸骨切开缝线、硫酸钡线和硅橡胶管构建复合缝线材料。通过左外侧开胸手术,将缝线穿过冠状窦、右心房并置于左冠状动脉下方,围绕二尖瓣环定位,然后收紧。
6只犬在手术期间因左心房、冠状窦或左冠状动脉出血死亡。3只犬术后因缝线压迫冠状动脉死亡。6只犬实现了满意的缝线放置,其中3只在因非心脏原因实施安乐死之前长期存活(6至26个月)。
用环形荷包缝线减小二尖瓣环直径无需体外循环。该手术技术难度大,需要详细了解冠状动脉解剖结构。当前的缝线设计价格低廉、不透射线且具有生物相容性;放置时无需特殊器械。
二尖瓣反流是犬最常见的心血管疾病,也是充血性心力衰竭最常见的原因。瓣环扩张是二尖瓣反流的结果。在二尖瓣环周围放置并收紧环形缝线可降低二尖瓣反流程度。