衍射双焦点和单焦点人工晶状体植入后的对比敏感度

Contrast sensitivity after implantation of diffractive bifocal and monofocal intraocular lenses.

作者信息

Haaskjold E, Allen E D, Burton R L, Webber S K, Sandvig K U, Jyrkkiö H, Leite E, Liekfeld A, Philipson B, Nyström A, Wollensak J

机构信息

Eye Department, National Hospital, Oslo, Norway.

出版信息

J Cataract Refract Surg. 1998 May;24(5):653-8. doi: 10.1016/s0886-3350(98)80260-5.

Abstract

PURPOSE

To compare contrast sensitivity (CS) after implantation of a diffractive bifocal intraocular lens (IOL) and a monofocal IOL of similar design.

SETTING

Seven European centers.

METHODS

In this randomized, prospective study, CS was tested 5 months after cataract and IOL implantation surgery in 115 patients with a diffractive bifocal IOL and 106 patients with a monofocal IOL. It was also tested in a subgroup of 38 patients who had bilateral implantation of a diffractive bifocal IOL. Contrast sensitivity was tested using the Vision Contrast Test System (VCTS).

RESULTS

In patients with a best corrected visual acuity (BCVA) of 1.0 or better, the CS at all spatial frequencies (1.5 to 18 cycles/degree), both at distance and near, was slightly lower in the bifocal IOL group than in the monofocal group. Mean values were within the normal range. In patients with a BCVA of less than 1.0, the CS was lower and the difference between the bifocal and monofocal groups was less. In patients with bilateral bifocal IOLs, CS was better when tested bilaterally than when testing the better eye alone. Pupil size affected the results to a small degree. Contrast sensitivity appeared to improve over time after implantation of a diffractive bifocal IOL.

CONCLUSIONS

In patients with cataract and no other eye pathology, the diffractive bifocal IOL with slightly reduce the CS at all spatial frequencies. In those with reduced visual acuity after cataract surgery, CS will be reduced accordingly. In this situation, the reduction from the diffractive bifocal optic would be minor.

摘要

目的

比较植入衍射双焦点人工晶状体(IOL)和类似设计的单焦点IOL后的对比敏感度(CS)。

设置

七个欧洲中心。

方法

在这项随机、前瞻性研究中,对115例植入衍射双焦点IOL的患者和106例植入单焦点IOL的患者在白内障和IOL植入手术后5个月进行CS测试。还对38例双侧植入衍射双焦点IOL的患者亚组进行了测试。使用视觉对比测试系统(VCTS)测试对比敏感度。

结果

最佳矫正视力(BCVA)为1.0或更好的患者中,双焦点IOL组在所有空间频率(1.5至18周期/度)下,无论是远视力还是近视力,CS均略低于单焦点组。平均值在正常范围内。BCVA小于1.0的患者中,CS较低,双焦点组和单焦点组之间的差异较小。在双侧植入双焦点IOL的患者中,双侧测试时的CS优于仅测试较好眼时。瞳孔大小对结果有轻微影响。植入衍射双焦点IOL后,对比敏感度似乎会随时间提高。

结论

在患有白内障且无其他眼部病变的患者中,衍射双焦点IOL会在所有空间频率下略微降低CS。在白内障手术后视力下降的患者中,CS也会相应降低。在这种情况下,衍射双焦点光学元件造成的降低较小。