Suppr超能文献

使用硫酸菲可用于评估肾小球基底膜的电荷选择性。

Assessment of the charge selectivity of glomerular basement membrane using Ficoll sulfate.

作者信息

Bolton G R, Deen W M, Daniels B S

机构信息

Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge 02139, USA.

出版信息

Am J Physiol. 1998 May;274(5):F889-96. doi: 10.1152/ajprenal.1998.274.5.F889.

Abstract

The extent to which the glomerular basement membrane (GBM) contributes to the charge selectivity of the glomerular capillary wall has been controversial. To reexamine this issue, the size and charge selectivity of filters made from isolated rat GBM were assessed, using polydisperse Ficoll and Ficoll sulfate as test macromolecules. Ficoll sulfate, a novel tracer with spherical shape synthesized for this purpose, exhibited little or no binding to serum albumin, thereby avoiding a major difficulty that has been reported with dextran sulfate. The sieving coefficients of Ficoll sulfate were not different from those of Ficoll at physiological ionic strength, although the values for Ficoll sulfate were depressed at low ionic strength. These results confirm that the GBM possesses fixed negative charges but suggest that its charge density is insufficient to confer significant charge selectivity under physiological conditions, where electrostatic interactions are relatively well screened. The sieving coefficients of Ficoll sulfate and Ficoll were elevated significantly and by similar amounts when bovine serum albumin (BSA) was present in the retentate at 4 g/dl. This could be explained as the combined effect of two nonspecific physical factors, namely, the reduction in filtration velocity due to the osmotic pressure of BSA and the effect on macromolecular partitioning of repulsive solute-solute interactions. The view that BSA does not affect the intrinsic properties of the GBM is supported also by the absence of an effect on the hydraulic permeability of isolated GBM. The sieving coefficient of BSA was roughly half that of Ficoll or Ficoll sulfate of similar Stokes-Einstein radius. Given the finding of negligible charge selectivity, this difference may be attributed to the nonspherical shape of albumin. The results suggest that, to the extent that isolated GBM is similar to GBM in vivo, the charge selectivity of the glomerular capillary wall must be due to the endothelial and/or epithelial cell layers.

摘要

肾小球基底膜(GBM)对肾小球毛细血管壁电荷选择性的贡献程度一直存在争议。为了重新审视这个问题,使用多分散的菲可和硫酸菲可作为测试大分子,评估了由分离的大鼠GBM制成的滤器的大小和电荷选择性。硫酸菲可是为此目的合成的一种新型球形示踪剂,与血清白蛋白几乎没有或没有结合,从而避免了硫酸葡聚糖所报道的一个主要困难。在生理离子强度下,硫酸菲可的筛分系数与菲可的筛分系数没有差异,尽管在低离子强度下硫酸菲可的值有所降低。这些结果证实GBM具有固定的负电荷,但表明在生理条件下其电荷密度不足以赋予显著的电荷选择性,在生理条件下静电相互作用得到了较好的屏蔽。当截留物中存在4 g/dl的牛血清白蛋白(BSA)时,硫酸菲可和菲可的筛分系数显著升高且升高幅度相似。这可以解释为两种非特异性物理因素的综合作用,即由于BSA的渗透压导致的过滤速度降低以及排斥性溶质 - 溶质相互作用对大分子分配的影响。BSA不影响GBM固有特性的观点也得到了对分离的GBM水力渗透性无影响的支持。BSA的筛分系数大约是具有相似斯托克斯 - 爱因斯坦半径的菲可或硫酸菲可筛分系数的一半。鉴于电荷选择性可忽略不计的发现,这种差异可能归因于白蛋白的非球形形状。结果表明,就分离的GBM在体内与GBM相似的程度而言,肾小球毛细血管壁的电荷选择性必定归因于内皮细胞层和/或上皮细胞层。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验