Dankers J, van den Elshout J, Ahr G, Brendel E, van der Heiden C
BCO Analytical Services, Breda, The Netherlands.
J Chromatogr B Biomed Sci Appl. 1998 Jun 12;710(1-2):115-20. doi: 10.1016/s0378-4347(98)00126-1.
For use in clinical studies, a fast and sensitive assay method was developed for the determination of nifedipine in human plasma samples. The assay method is based on tandem mass spectrometry detection (HPLC-MS-MS). The effect of flow injection as well as HPLC separation on the results of the nifedipine determination were evaluated. The limit of quantification is 0.5 ng/ml and the accuracy (as determined by spiking recovery) was found to be good.