Suppr超能文献

Determination of terazosin in human plasma, using high-performance liquid chromatography with fluorescence detection.

作者信息

Sekhar E C, Rao T R, Sekhar K R, Naidu M U, Shobha J C, Rani P U, Kumar T V, Kumar V P

机构信息

Department of Clinical Pharmacology and Therapeutics, Nizam's Institute of Medical Sciences, Panjagutta, Hyderabad, India.

出版信息

J Chromatogr B Biomed Sci Appl. 1998 Jun 12;710(1-2):137-42. doi: 10.1016/s0378-4347(98)00120-0.

Abstract

A selective, sensitive, rapid and reproducible high-performance liquid chromatographic method for the determination of terazosin in plasma is described. The structurally related compound prazosin was used as an internal standard. The method comprises extraction with methylene chloride followed by chromatography on a C18 reversed-phase column. The compounds were detected using spectrofluorimetry. The absolute recoveries were more than 90% with a minimal detection of 1 ng/ml and calibration curve was linear between 1 and 80 ng/ml.