Suppr超能文献

通过电穿孔控制寡核苷酸局部递送的参数。

Parameters controlling topical delivery of oligonucleotides by electroporation.

作者信息

Regnier V, Le Doan T, Préat V

机构信息

Unité de Pharmacie Galénique, Université Catholique de Louvain, Brussels, Belgium.

出版信息

J Drug Target. 1998;5(4):275-89. doi: 10.3109/10611869808995881.

Abstract

Electroporation, using high voltage electrical pulses has been recognized as a powerful method for delivering macromolecules such as DNA and proteins in cells, or smaller molecules through the skin. Transdermal electroporation could combine targeted delivery of drugs to the skin and permeabilization of skin cells, suggesting that electroporation could be an interesting alternative for topical delivery of oligonucleotides. This work is devoted to the determination of the electroporation parameters that allow optimal delivery of oligonucleotides to the viable tissues of hairless rat skin in vitro. Phosphorothioate derivatives were preferred to the phosphodiester congeners as the former were found to be much less degraded when extracted from the tissues. Long duration (100-500 ms)--medium voltage (100-200 V)--exponentially decaying pulses appeared to be the best conditions for delivering oligonucleotides to the skin. The oligonucleotide quantity permeating the viable tissues of the skin was controlled by the selection of the electrical parameters of the pulses (voltage, pulse time and number of pulses) or by the ON concentration in the donor compartment. After delivery by electroporation, therapeutic levels of oligonucleotides were reached in the viable tissues of the skin (above 1 microM or 10 microM in intact or stripped skin respectively). Taken together, our results show that electroporation could be an interesting method for the delivery of oligonucleotides to the skin.

摘要

使用高压电脉冲的电穿孔已被公认为是一种将大分子(如DNA和蛋白质)导入细胞,或使小分子透过皮肤的有效方法。经皮电穿孔可将药物靶向递送至皮肤并使皮肤细胞通透化,这表明电穿孔可能是寡核苷酸局部递送的一种有趣替代方法。这项工作致力于确定能在体外将寡核苷酸最佳递送至无毛大鼠皮肤活组织的电穿孔参数。硫代磷酸酯衍生物比磷酸二酯同类物更受青睐,因为前者从组织中提取时降解程度低得多。长持续时间(100 - 500毫秒)、中等电压(100 - 200伏)、指数衰减脉冲似乎是将寡核苷酸递送至皮肤的最佳条件。透过皮肤活组织的寡核苷酸量可通过选择脉冲的电参数(电压、脉冲时间和脉冲数)或供体室中的ON浓度来控制。通过电穿孔递送后,在皮肤活组织中达到了治疗水平的寡核苷酸(完整皮肤或去皮皮肤中分别高于1微摩尔或10微摩尔)。综上所述,我们的结果表明电穿孔可能是一种将寡核苷酸递送至皮肤的有趣方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验