Suppr超能文献

LSI HER-2/neu 光谱橙和CEP 17 光谱绿双色脱氧核糖核酸探针试剂盒的重现性。用于石蜡包埋标本中基因扩增的计数:一项多中心临床验证研究。

Reproducibility of LSI HER-2/neu SpectrumOrange and CEP 17 SpectrumGreen Dual Color deoxyribonucleic acid probe kit. For enumeration of gene amplification in paraffin-embedded specimens: a multicenter clinical validation study.

作者信息

Masood S, Bui M M, Yung J F, Mark H F, Wong E Y, Birkmeier J M, Yang S J, Hsu P

机构信息

Department of Pathology, University of Florida Health Science Center, Jacksonville 32206, USA.

出版信息

Ann Clin Lab Sci. 1998 Jul-Aug;28(4):215-23.

PMID:9715348
Abstract

Overexpression and/or amplification of HER-2/neu gene have been found to be prognostic and predictive in breast and other cancers. Fluorescence in situ hybridization (FISH) assay, with its sensitivity and specificity, can be a superior method of detection when its performance characteristics are demonstrated. A multicenter study was initiated to evaluate the reproducibility of the LSI HER-2/neu SpectrumOrange and CEP 17 SpectrumGreen Dual Color DNA Probe for enumeration of both the HER-2/neu gene and chromosome 17 (signals) in interphase cells. Section slides were prepared from four cell lines (H, E, R, and N) with known ratios of the HER-2/neu to CEP 17 copy numbers (approximately H = 1.10, E = 1.70, R = 4.50, N = 9.0). The study variable was the ratios of the HER-2/neu to chromosome 17 copy numbers. Reproducibility with respect to assay, site, lot, day and reader was evaluated at 3 centers. Out of 120 specimen slides, 100 percent were successfully assayed. There were no significant differences among: (1) four repeated assays of the same specimen (p = 0.99), (2) the four probe lots (p = 0.33), or (3) the four study days (p = 0.54). There was statistically significant, but not important differences among centers and between readers. The ratios of the HER-2/neu to chromosome 17 copy numbers were estimated with accuracy and precision; the mean ratios (and sd) for specimens, H, E, R, and N were 1.05 (0.06), 1.81 (0.12), 4.48 (0.28), and 8.60 (1.23), respectively. In summary, assays with the LSI HER-2/neu and CEP 17 Dual Color DNA Probe Kit, conducted at three sites by 6 different technicians, over 8 assay days, using kits from four lots, were performed with a high success rate in paraffin-embedded specimens. The signal enumeration was also accurate and precise. This study demonstrated that the results obtained by using the LSI HER-2/neu SpectrumOrange and CEP 17 SpectrumGreen Dual Color DNA Probe Kit are reliable and reproducible.

摘要

已发现HER-2/neu基因的过表达和/或扩增在乳腺癌及其他癌症中具有预后和预测价值。荧光原位杂交(FISH)检测凭借其灵敏度和特异性,在展现其性能特征时可成为一种更优的检测方法。启动了一项多中心研究,以评估LSI HER-2/neu SpectrumOrange和CEP 17 SpectrumGreen双色DNA探针在间期细胞中对HER-2/neu基因和17号染色体(信号)进行计数的可重复性。从四种细胞系(H、E、R和N)制备切片载玻片,这些细胞系的HER-2/neu与CEP 17拷贝数比例已知(大致为H = 1.10、E = 1.70、R = 4.50、N = 9.0)。研究变量为HER-2/neu与17号染色体拷贝数的比例。在3个中心评估了检测、位点、批次、日期和阅片者方面的可重复性。在120张标本载玻片中,100%成功进行了检测。在以下方面无显著差异:(1)同一样本的四次重复检测(p = 0.99),(2)四个探针批次(p = 0.33),或(3)四个研究日期(p = 0.54)。中心之间以及阅片者之间存在统计学上显著但不重要的差异。HER-2/neu与17号染色体拷贝数的比例估计准确且精确;样本H、E、R和N的平均比例(及标准差)分别为1.05(0.06)、1.81(0.12)、4.48(0.28)和8.60(1.23)。总之,由6名不同技术人员在3个位点进行的、历时8个检测日、使用来自四个批次试剂盒的LSI HER-2/neu和CEP 17双色DNA探针试剂盒检测,在石蜡包埋标本中的成功率很高。信号计数也准确且精确。这项研究表明,使用LSI HER-2/neu SpectrumOrange和CEP 17 SpectrumGreen双色DNA探针试剂盒获得的结果可靠且可重复。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验