Suppr超能文献

胶束电动色谱法快速测定农药的正辛醇-水分配系数

Rapid estimation of octanol-water partition coefficients of pesticides by micellar electrokinetic chromatography.

作者信息

Wu Y S, Lee H K, Li S F

机构信息

Department of Chemistry, National University of Singapore, Republic of Singapore.

出版信息

Electrophoresis. 1998 Jul;19(10):1719-27. doi: 10.1002/elps.1150191032.

Abstract

Micellar electrokinetic chromatography (MEKC) was evaluated as a new technique for the rapid estimation of octanol-water partition coefficient (logKow). Retention measurements for more than 40 reference pesticides with varied structural characteristics and hydrophobicity were carried out in two MEKC systems, based on sodium dodecyl sulfate (SDS) and sodium cholate (SC), respectively. To enable an accurate determination of capacity factors in the SC-MEKC system, cypermethrin (a synthetic pyrethroid insecticide) was utilized instead of Sudan III as the SC micelle tracer, since a few highly hydrophobic pesticides were found to elute after Sudan III. The linear correlation between logarithmic capacity factor (logk') and logKow in the two systems was examined. It was found that, under the typical buffer condition (10 mM sodium phosphate with 60 mM surfactant, pH 7.0), the SDS-MEKC system provided a somewhat wider dynamic range for hydrophobicity (logKow from -1.0 to 4.5). However, the correlation of logk' with logKow was not very high when all the reference pesticides were included in one single calibration set. For the SC-MEKC system, the dynamic range for logKow was in the range of 1.0-5.5, and a good linear correlation existed between logk' and logKow, even when all reference pesticides were incorporated into a single calibration group. By comparing the regression line of the reference pesticides with that of a group of simple aromatic derivatives, it was discovered that molecular size and functionality posed a less significant effect on the measurement of logKow in the SC-MEKC system than in the SDS-MEKC system. Thus, SC-MEKC shall be the system of choice for the estimation of logKow. The typical error on logKow determination using the current MEKC technique was within 0.5 units, suggesting that MEKC can be a valuable complement to reversed phase high performance liquid chromatography (RP-HPLC) for the indirect determination of logKow. Besides maintaining all the advantages of the HPLC approach, the MEKC technique showed some unique benefits, such as better inter-column reproducibility, higher throughput, and less handling of toxic pesticides and solvents.

摘要

胶束电动色谱法(MEKC)被评估为一种快速估算正辛醇 - 水分配系数(logKow)的新技术。分别基于十二烷基硫酸钠(SDS)和胆酸钠(SC),在两个MEKC系统中对40多种具有不同结构特征和疏水性的参考农药进行了保留测定。为了在SC - MEKC系统中准确测定容量因子,使用氯氰菊酯(一种合成拟除虫菊酯类杀虫剂)代替苏丹III作为SC胶束示踪剂,因为发现一些高疏水性农药在苏丹III之后洗脱。研究了两个系统中对数容量因子(logk')与logKow之间的线性相关性。结果发现,在典型的缓冲条件(10 mM磷酸钠与60 mM表面活性剂,pH 7.0)下,SDS - MEKC系统为疏水性提供了稍宽的动态范围(logKow从 - 1.0到4.5)。然而,当所有参考农药包含在一个单一校准组中时,logk'与logKow的相关性不是很高。对于SC - MEKC系统,logKow的动态范围在1.0 - 5.5之间,即使所有参考农药都纳入一个单一校准组,logk'与logKow之间也存在良好的线性相关性。通过比较参考农药的回归线与一组简单芳香族衍生物的回归线,发现与SDS - MEKC系统相比,分子大小和官能团对SC - MEKC系统中logKow测量的影响较小。因此,SC - MEKC应是估算logKow的首选系统。使用当前MEKC技术测定logKow的典型误差在0.5个单位以内,这表明MEKC可作为反相高效液相色谱法(RP - HPLC)间接测定logKow的有价值补充。除了保持HPLC方法的所有优点外,MEKC技术还显示出一些独特的优势,如更好的柱间重现性、更高的通量以及对有毒农药和溶剂的处理更少。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验