Suppr超能文献

三种类型的半肢石膏对从马尸体肢体的第三掌骨和近端指骨记录的体外骨应变的影响。

Effect of three types of half-limb casts on in vitro bone strain recorded from the third metacarpal bone and proximal phalanx in equine cadaver limbs.

作者信息

Schneider R K, Ratzlaff M C, White K K, Hopper S A

机构信息

Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Washington State University, Pullman 99164, USA.

出版信息

Am J Vet Res. 1998 Sep;59(9):1188-93.

PMID:9736401
Abstract

OBJECTIVE

To determine effect of 3 half-limb casts on bone strains recorded from the proximal phalanx (P-1) and third metacarpal bone (MCIII) of equine cadaver limbs, using a mechanical testing machine.

ANIMALS

12 equine cadaver limbs and 4 live horses.

PROCEDURE

Bone strains were recorded at middorsal P-1 and the dorsal cortical aspect of the distal third of MCIII while limbs were variably loaded with 100 to 1,000 lb of force. To determine ability of the cast to protect the distal portion of the limb from weight-bearing loads, strains were recorded with the limb in 1 of the 3 casts and with it unsupported. To determine cast-induced discomfort, weight-supporting and transfixation pin casts were evaluated on 2 live horses

RESULTS

All 3 casts significantly reduced bone strain at P-1. Significant differences were observed: mean 61% reduction for the standard half-limb cast, 84% for the transfixation pin cast, and 97% for the weight-supporting cast at weight-bearing force of 500 lb. Only the weight-supporting cast significantly reduced strains recorded from MCIII. The weight-supporting cast was not well tolerated by 2 live horses.

CONCLUSIONS

The 3 casts significantly reduced transfer of weight-bearing forces to the distal portion of the limb. The weight-supporting cast effectively reduced strain on the P-1 to near 0, but was well tolerated by live horses. The transfixation pin cast reduced strain on the P-1 by > 80% at weight-bearing loads of 500 lb, and live horses were comfortable. Standard half-limb casts significantly reduced strains on the P-1, but to a lesser degree than did other casts.

摘要

目的

使用机械测试机确定3种半肢管型对马尸体肢体近端指骨(P-1)和第三掌骨(MCIII)记录的骨应变的影响。

动物

12个马尸体肢体和4匹活马。

方法

在肢体承受100至1000磅力的不同负荷时,记录P-1背中部和MCIII远端三分之一背侧皮质的骨应变。为了确定管型保护肢体远端免受负重负荷的能力,在肢体处于3种管型之一且无支撑的情况下记录应变。为了确定管型引起的不适,对2匹活马评估了承重和固定针管型。

结果

所有3种管型均显著降低了P-1处的骨应变。观察到显著差异:在500磅的负重下,标准半肢管型平均降低61%,固定针管型降低84%,承重管型降低97%。只有承重管型显著降低了MCIII记录的应变。2匹活马对承重管型的耐受性不佳。

结论

3种管型均显著减少了负重力量向肢体远端的传递。承重管型有效地将P-1处的应变降低至接近0,但活马对其耐受性良好。在500磅的负重下,固定针管型使P-1处的应变降低超过80%,且活马感觉舒适。标准半肢管型显著降低了P-1处的应变,但程度小于其他管型。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验