Suppr超能文献

MAVIS:一种用于测量伤口面积和体积的非侵入性仪器。面积和体积测量仪器系统。

MAVIS: a non-invasive instrument to measure area and volume of wounds. Measurement of Area and Volume Instrument System.

作者信息

Plassmann P, Jones T D

机构信息

University of Glamorgan, Department of Computer Studies, Pontypridd, Mid Glamorgan, UK.

出版信息

Med Eng Phys. 1998 Jul;20(5):332-8. doi: 10.1016/s1350-4533(98)00034-4.

Abstract

Accurate measurement of the physical size of wounds is vital for assessment of the progress of healing. An instrument has been developed to measure area and volume of skin wounds, ulcers, and pressure sores. MAVIS--Measurement of Area and Volume Instrument System-is based on the principle of colour coded structured light. A set of parallel stripes of alternating colours is projected onto the wound area at an angle of approximately 45 degrees and is recorded by a CCD camera. From the known position of the focal points of projector and camera, and from the observed intersection points of the stripes of light with the wound surface, a computer calculates a three-dimensional map of the observed wound. The volume of the wound is defined as the volume of the region sandwiched between the observed surface and the original healthy skin surface which is simulated by cubic spline interpolation. This paper compares the performance of the instrument with three traditional wound measurement techniques using results obtained from a clinical trial involving 50 patients. Traditional area measurement techniques such as transparency tracings produce results with standard deviations between 4% (large wounds) and up to 20% (small wounds) of the measured mean value. MAVIS measurements reduce these standard deviations by 3-5%. Measuring the wound volume by alginate casts produces errors in volume figures between 5% and 40%. Standard deviations of MAVIS results are 5% smaller on average. The results demonstrate that MAVIS yields more reproducible results with a minimum of inter-observer error. The instrument does not make contact with the wound, provided visual records and measurements are made in less then 5 min. It is not suitable for undermined, very deep or very large wounds.

摘要

准确测量伤口的实际大小对于评估愈合进程至关重要。现已开发出一种仪器来测量皮肤伤口、溃疡和压疮的面积与体积。MAVIS(面积和体积测量仪器系统)基于彩色编码结构光原理。一组交替颜色的平行条纹以约45度角投射到伤口区域,并由电荷耦合器件(CCD)相机记录。根据投影仪和相机焦点的已知位置,以及光线条纹与伤口表面观察到的交点,计算机计算出观察到的伤口的三维地图。伤口体积定义为通过三次样条插值模拟的观察表面与原始健康皮肤表面之间夹着的区域的体积。本文使用来自涉及50名患者的临床试验结果,将该仪器的性能与三种传统伤口测量技术进行了比较。传统的面积测量技术,如透明描图,其测量结果的标准差在测量平均值的4%(大伤口)到20%(小伤口)之间。MAVIS测量将这些标准差降低了3 - 5%。通过藻酸盐铸型测量伤口体积会在体积数值上产生5%到40%的误差。MAVIS结果的标准差平均小5%。结果表明,MAVIS产生的结果更具可重复性,观察者间误差最小。只要在不到5分钟内进行视觉记录和测量,该仪器就不会与伤口接触。它不适用于潜行性、非常深或非常大的伤口。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验