Suppr超能文献

Safety of dobutamine-atropine stress myocardial perfusion scintigraphy.

作者信息

Elhendy A, Valkema R, van Domburg R T, Bax J J, Nierop P R, Cornel J H, Geleijnse M L, Reijs A E, Krenning E P, Roelandt J R

机构信息

Thoraxcenter and Department of Nuclear Medicine, University Hospital Rotterdam-Dijkzigt, Erasmus University, Rotterdam, The Netherlands.

出版信息

J Nucl Med. 1998 Oct;39(10):1662-6.

PMID:9776264
Abstract

UNLABELLED

Dobutamine stress testing is increasingly used for the diagnosis and functional evaluation of coronary artery disease. However, the relationship between myocardial perfusion abnormalities and complications of the test has not been studied.

METHODS

We studied the hemodynamic profile, safety and feasibility of dobutamine (up to 40 microg/kg/min)-atropine (up to 1 mg) stress myocardial perfusion SPECT imaging (with 201TI, 99mTc-MIBI or tetrofosmin) in a consecutive series of 1076 patients (age = 59 +/- 11 yr, 50% with previous myocardial infarction) referred for evaluation of myocardial ischemia.

RESULTS

No infarction or death occurred during the test. The test was considered feasible (achievement of 85% of the target heart rate or an ischemic endpoint) in 1005 patients (94%). Hypotension (systolic blood pressure drop > or = 40 mm Hg) occurred in 37 patients (3.4%). Independent predictors were higher baseline systolic blood pressure (p < 0.0001), number of ischemic segments (p < 0.05) and age (p < 0.05). Supraventricular tachyarrhythmias occurred in 48 patients (4.4%). Independent predictors were fixed perfusion defect (infarction) score (p < 0.005) and age (p < 0.05). Ventricular tachycardia occurred in 41 patients (3.8%). Independent predictors were infarction score (p < 0.01) and male gender (p < 0.05). All arrhythmias terminated spontaneously or after metoprolol administration.

CONCLUSION

Dobutamine-atropine myocardial perfusion scintigraphy is a feasible method for the evaluation of coronary artery disease with a safety profile and feasibility comparable to those reported for dobutamine stress echocardiography. Patients with more severe fixed perfusion abnormalities are at a higher risk of developing tachyarrhythmias during the test.