Pedersen P V, Brown K F
J Pharm Sci. 1976 Oct;65(10):1442-7. doi: 10.1002/jps.2600651007.
The dissolution of the 60-85-mesh fraction os recording, flow-through dissolution apparatus equipped with a dissolution cell; it was particularly suitable for kinetic analysis of multiparticulate systems. By using a time-scaling approach, experimental data are compared with theoretical calculations to evaluate, quantitatively, which of three single-particle dissolution models best describes the data and how well the multiparticulate kinetics can be explained mathematically. The nonspherical tolbutamide particles are replaced in the calculations by a hypothetical system of spherical particles that appears to be log-normally distributed. This procedure permits the calculation of the intrinsic dissolution profile, considering both size distribution and particle shape effects.
60-85目级分的溶出度测定采用配备溶出池的流通式溶出装置进行;它特别适用于多颗粒系统的动力学分析。通过采用时间标度法,将实验数据与理论计算结果进行比较,以定量评估三种单颗粒溶出模型中哪一种最能描述数据,以及多颗粒动力学在数学上能得到多好的解释。在计算中,用一个似乎呈对数正态分布的假设球形颗粒系统取代了非球形甲苯磺丁脲颗粒。该程序允许在考虑尺寸分布和颗粒形状效应的情况下计算固有溶出曲线。