使用新型Coe射频端孔导管成功对一名新生儿的闭锁肺动脉瓣膜进行经导管穿孔。

Successful transcatheter perforation of the atretic pulmonary valve membrane in a newborn using the new Coe radiofrequency end hole catheter.

作者信息

Cheatham J P, Coe J Y, Kugler J D, Fletcher S E, Tower A J

机构信息

Joint Division of Pediatric Cardiology, University of Nebraska and Creighton University at Children's Hospital, Omaha 68114, USA.

出版信息

Cathet Cardiovasc Diagn. 1998 Oct;45(2):162-6. doi: 10.1002/(sici)1097-0304(199810)45:2<162::aid-ccd13>3.0.co;2-n.

Abstract

The new 2 French Coe radiofrequency (RF) end hole catheter was first used to successfully perforate the atretic pulmonary valve membrane using an antegrade approach in a newborn with intact ventricular septum (IVS). Nine watts of energy for 8 sec was required with simultaneous delivery of a 0.014 in. coronary guidewire coaxially through the end hole RF catheter for balloon valvuloplasty. This new ringed-tip end hole RF catheter offers considerable advantages to the pediatric interventionalist in the transcatheter therapy in neonates with pulmonary atresia (PA) and IVS.

摘要

新型2法国规格的Coe射频(RF)端孔导管首次用于一名室间隔完整(IVS)的新生儿,采用顺行法成功穿透闭锁的肺动脉瓣膜。在通过端孔RF导管同轴同时输送一根0.014英寸冠状动脉导丝进行球囊瓣膜成形术时,需要8秒钟施加9瓦能量。这种新型带环尖端端孔RF导管为患有肺动脉闭锁(PA)和IVS的新生儿经导管治疗的儿科介入专家提供了相当大的优势。