• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Detection system for reaction-rate analysis in a low-volume proteinase-inhibition assay.

作者信息

Ambrose W P, Semin D J, Robbins D L, Van Orden A, Kashem M A, Hamilton S A, Nelson R M, Jett J H, Keller R A

机构信息

Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.

出版信息

Anal Biochem. 1998 Oct 15;263(2):150-7. doi: 10.1006/abio.1998.2786.

DOI:10.1006/abio.1998.2786
PMID:9799526
Abstract

High-throughput screening of large combinatorial chemical libraries in biochemical assays will benefit from reduced reagent volume and increased speed of measurement. Standard assays typically are performed in 96-well microtiter plates having 200-microL well volumes and up to an hour of incubation time. In this paper, we demonstrate a technique for precise and rapid measurement of the progress of an enzymatic reaction and its inhibition with reduced volume and time (for this work, the assay was mixed at the 200-microL level and detected in 2-microL volumes with minutes of total assay time). Directly measuring the enzyme activity in the small volume format yields a precise value for the median inhibitory concentration (IC50) of an inhibitor compound. The model assay is the endoproteolytic cleavage of a small fluorogenic peptide by human neutrophil collagenase (MMP-8). The fluorogenic peptide was labeled at one end with a UV/blue fluorophore (N-methylanthranilyl) and at the other end with a quencher (dinitrophenol). To generate inhibition data, a hydroxamate peptide analog inhibitor of collagenase, actinonin, was included in the reaction. The experiments were performed using ultraviolet laser illumination (325 nm wavelength) and parallel fluorescence detection by a cooled, charge-coupled-device camera system to increase sensitivity and speed. The assay volume was reduced to 2 microL for data collection, and the total time for mixing, incubation, and measurement was less than 6 min. For comparison to a standard format, the same assay was performed in a 96-well microtiter plate in 200 microL using 30 min of incubation and measurement in a microtiter plate fluorimeter. Median inhibitory concentrations (IC50) for actinonin of 73 +/- 16 and 100 +/- 14 nM were obtained in the 2- and 200-microL assays, respectively. One concern with assay miniaturization and increases in throughput is a potential loss of precision and accuracy. Laser excitation and parallel detection of fluorescence is a promising approach for increased speed and reduced cost without loss of precision for proteinase inhibition assays.

摘要

相似文献

1
Detection system for reaction-rate analysis in a low-volume proteinase-inhibition assay.
Anal Biochem. 1998 Oct 15;263(2):150-7. doi: 10.1006/abio.1998.2786.
2
A high-density screening format for encoded combinatorial libraries: assay miniaturization and its application to enzymatic reactions.一种用于编码组合文库的高密度筛选形式:分析小型化及其在酶促反应中的应用。
Anal Biochem. 1997 Mar 1;246(1):20-9. doi: 10.1006/abio.1996.9958.
3
Assay of collagenase activity for native triple-helical collagen using capillary gel electrophoresis with laser-induced fluorescence detection.使用毛细管凝胶电泳结合激光诱导荧光检测法测定天然三螺旋胶原蛋白的胶原酶活性。
J Chromatogr B Analyt Technol Biomed Life Sci. 2004 Oct 5;809(2):251-6. doi: 10.1016/j.jchromb.2004.06.036.
4
Miniaturization of a hepatitis C virus RNA polymerase assay using a -102 degrees C cooled CCD camera-based imaging system.使用基于-102℃冷却电荷耦合器件(CCD)相机的成像系统对丙型肝炎病毒RNA聚合酶检测进行小型化。
Anal Biochem. 2001 Mar;290(2):214-20. doi: 10.1006/abio.2001.4991.
5
Improved reliability of the rapid microtiter plate assay using recombinant enzyme in predicting CYP2D6 inhibition in human liver microsomes.
Drug Metab Dispos. 1999 Apr;27(4):436-9.
6
Fluorescence-quenching-based homogeneous caspase-3 activity assay using photon upconversion.基于光上转换的荧光猝灭型细胞凋亡蛋白酶-3 活性检测试剂盒
Anal Chim Acta. 2012 May 6;725:67-73. doi: 10.1016/j.aca.2012.03.010. Epub 2012 Mar 15.
7
High-throughput flow cytometry: validation in microvolume bioassays.高通量流式细胞术:微量生物测定中的验证
Cytometry A. 2003 May;53(1):55-65. doi: 10.1002/cyto.a.10035.
8
Determination of matrix metalloproteinase activity using biotinylated gelatin.使用生物素化明胶测定基质金属蛋白酶活性
Anal Biochem. 2000 Nov 1;286(1):149-55. doi: 10.1006/abio.2000.4798.
9
A simple portable electroluminescence illumination-based CCD detector.一种基于电致发光照明的简单便携式电荷耦合器件探测器。
Methods Mol Biol. 2009;503:259-72. doi: 10.1007/978-1-60327-567-5_14.
10
Miniaturization of absorbance assays using the fluorescent properties of white microplates.利用白色微孔板的荧光特性实现吸光度测定的微型化。
Anal Biochem. 2005 Jul 15;342(2):254-9. doi: 10.1016/j.ab.2005.04.029.