Swatland H J, Uttaro B, Goldenberg A A, Lu Z
Department of Animal and Poultry Science, University of Guelph, Ontario, Canada.
J Anim Sci. 1998 Oct;76(10):2614-8. doi: 10.2527/1998.76102614x.
A robot was used to make fiber-optic reflectance measurements from 400 to 700 nm in 10-nm increments at six sites, 10 cm apart, along the length of 48 pork loins. Meat quality was assessed in the longissimus dorsi near the thoracolumbar junction using 1) a bag-drip method for fluid loss, 2) a subjective evaluation of wetness, 3) a colorimeter measurement of paleness (CIE L), and 4) a subjective evaluation for Japanese pork color scores (JPCS). Sorting of the loins in the commercial plant from which they originated was correlated (P < .01) with fluid loss (r=.57), with wetness scores (r=-.57), with CIE L* (r=.71), and with JPCS (r=-.64). Laboratory measurements of pH at the site of meat quality assessment were correlated (P < .01) with fluid loss (r=-.61), with wetness scores (r=.65), with CIE L* (r=-.74), and with JPCS (r=.77). Average spectra obtained robotically were correlated (P < .01) with fluid loss (r=.56 at 670 nm, and R=.76 adding 560 and 540 nm), with wetness score (r=-.65 at 480 nm, and R=.75 adding 530 and 570 nm), with CIE L* (r=.76 at 480 nm, and R=.82 adding 690 and 520 nm), and with JPCS (r=-.70). In sorting loins that were all categorized as normal at the plant, mean reflectance data collected robotically were correlated with fluid loss, r=.42 (P > .05) at 700 nm and R=.58 (P > .05) adding 430 nm; with wetness score, r=.25 (P > .05); with CIE L*, r=.58 (P < .025) at 700 nm; and with JPCS, r=-.71 (P < .01) at 700 nm. Thus, as well as detecting obvious PSE loins, the robotic probe also had a limited capability to sort loins all categorized as normal at the plant.
使用一台机器人沿着48块猪里脊肉的长度,在六个间距为10厘米的部位进行光纤反射率测量,测量范围为400至700纳米,间隔10纳米。在胸腰结合部附近的背最长肌处评估肉质,方法如下:1)采用袋滴法测量失水量;2)对湿度进行主观评估;3)用色度计测量肉色苍白度(CIE L*);4)对日本猪肉颜色评分(JPCS)进行主观评估。这些猪里脊肉在其来源的商业工厂中的分类与失水量(r = 0.57)、湿度评分(r = -0.57)、CIE L*(r = 0.71)和JPCS(r = -0.64)相关(P < 0.01)。在肉质评估部位进行的实验室pH测量与失水量(r = -0.61)、湿度评分(r = 0.65)、CIE L*(r = -0.74)和JPCS(r = 0.77)相关(P < 0.01)。通过机器人自动获得的平均光谱与失水量(670纳米处r = 0.56,加入560和540纳米后R = 0.76)、湿度评分(480纳米处r = -0.65,加入530和570纳米后R = 0.75)、CIE L*(480纳米处r = 0.76,加入690和520纳米后R = 0.82)和JPCS(r = -0.70)相关(P < 0.01)。在对工厂中所有归类为正常的猪里脊肉进行分类时,通过机器人自动收集的平均反射率数据与失水量相关,700纳米处r = 0.42(P > 0.05),加入430纳米后R = 0.58(P > 0.05);与湿度评分相关,r = 0.25(P > 0.05);与CIE L*相关,700纳米处r = 0.58(P < 0.025);与JPCS相关,700纳米处r = -0.71(P < 0.01)。因此,除了检测明显的PSE猪里脊肉外,机器人探头在对工厂中所有归类为正常的猪里脊肉进行分类方面也有一定能力。