Relationship between CT number and electron density, scatter angle and nuclear reaction for hadron-therapy treatment planning.

作者信息

Matsufuji N, Tomura H, Futami Y, Yamashita H, Higashi A, Minohara S, Endo M, Kanai T

机构信息

Division of Accelerator Physics and Engineering, National Institute of Radiological Sciences, Chiba, Chiba, Japan.

出版信息

Phys Med Biol. 1998 Nov;43(11):3261-75. doi: 10.1088/0031-9155/43/11/007.

Abstract

The precise conversion of CT numbers to their electron densities is essential in treatment planning for hadron therapy. Although some conversion methods have already been proposed, it is hard to check the conversion accuracy during practical therapy. We have estimated the CT numbers of real tissues by a calculational method established by Mustafa and Jackson. The relationship between the CT numbers and the electron densities was investigated for various body tissues as well as some tissue-equivalent materials used for a conversion to check the accuracy of the current conversion methods. The result indicates a slight disagreement at the high-CT-number region. A precise estimation of the multiple scattering, nuclear reaction and range straggling of incident particles has been considered as being important to realize higher-level conformal therapy in the future. The relationship between these parameters and the CT numbers was also investigated for tissues and water. The result shows that it is sufficiently practical to replace these parameters for real tissues with those for water by adjusting the density.