Müller C A, Schavan R, Frigg R, Perren S M, Pfister U
AO/ASIF Development Institute, Davos-Platz, Switzerland.
J Orthop Trauma. 1998 Nov-Dec;12(8):540-6. doi: 10.1097/00005131-199811000-00002.
To measure the differences in intramedullary (IM) pressure for commercial reamer systems.
IM pressure values for the following systems were measured: AO, Biomet, Howmedica grey reamer, Richards, and Zimmer. To investigate the influence of shaft diameter, the AO reamer head was additionally connected to a small shaft (A6/A7). The pressures were measured in plexiglass tubes filled with a mixture of petroleum jelly and paraffin oil with flow properties at 20 degrees C equivalent to those of bovine medullary fat at 36 degrees C. The reaming assemblies were inserted into the tubes using a materials testing machine at a constant speed. In addition, pressure measurements were made using five pairs of human femora to compare Biomet reamers with the AO reamer with thin, flexible drives (A6/A7).
The following pressure distributions were obtained (millimeters of mercury; mean value +/- standard deviation): 9.5-millimeter reamer: low for Biomet (272+/-39); moderate for Richards (810+/-101); and high for Howmedica (990+/-132), AO conventional (1,000+/-97), and Zimmer (1,140+/-183); 13.0-millimeter reamer: low for Biomet (132+/-21), Howmedica (204+/-45), and Zimmer (226+/-33); moderate for AO conventional (474+/-42); and very high for Richards (1,734+/-127). The second worst system (AO conventional: 1,000+/-97) became the second best system by simple reduction of the shaft diameter (A6/A7: 378+/-33).
A comparison of shaft diameters and pressure increase clearly showed that the system with the thinnest shaft produced the lowest pressure values and vice versa.
测量商用扩髓系统的髓内(IM)压力差异。
测量了以下系统的IM压力值:AO、Biomet、豪美迪灰色扩髓钻、理查兹和捷迈。为研究杆直径的影响,AO扩髓钻头还额外连接到一个小直径杆(A6/A7)上。压力在填充有凡士林和石蜡油混合物的有机玻璃管中测量,该混合物在20℃时的流动特性与36℃时牛髓脂肪的流动特性相当。使用材料试验机以恒定速度将扩髓组件插入管中。此外,使用五对人股骨进行压力测量,以将Biomet扩髓钻与带有细柔性驱动装置(A6/A7)的AO扩髓钻进行比较。
获得以下压力分布(毫米汞柱;平均值±标准差):9.5毫米扩髓钻:Biomet较低(272±39);理查兹适中(810±101);豪美迪、AO传统型和捷迈较高(分别为990±132、1000±97和1140±183);13.0毫米扩髓钻:Biomet、豪美迪和捷迈较低(分别为132±21、204±45和226±33);AO传统型适中(474±42);理查兹非常高(1734±127)。第二差的系统(AO传统型:1000±97)通过简单减小杆直径(A6/A7:378±33)变为第二好的系统。
杆直径与压力增加的比较清楚地表明,杆最细的系统产生的压力值最低,反之亦然。