Normalizing intermethod free triiodothyronine patient results: need for commutable materials.

作者信息

Cattozzo G, Scarsi G, Franzini C

机构信息

Laboratorio di Analisi, Ospedale C. Ondoli, Angera (VA), Italia.

出版信息

Clin Chem Lab Med. 1998 Oct;36(10):777-80. doi: 10.1515/CCLM.1998.138.

DOI:10.1515/CCLM.1998.138
PMID:9853805
Abstract

The aim of this work was to check the suitability of control materials to normalize intermethod results for the measurement of free triiodothyronine in patient sera. In the main experiment, 108 patient sera and 11 commercially available control materials were assayed by a pair of methods. In a confirmatory experiment, two of the control materials and 142 patient sera were assayed with an alternative pair of methods. In the main experiment, the intermethod variability of 6/11 control materials differed significantly from that of patient sera (i. e. control materials were non-commutable). Recalculation of patient results using control materials as calibrators lowered the intermethod difference only if commutable materials were used. The confirmatory experiment demonstrated that the pattern of commutability changed if a different pair of methods was used. We conclude that in the case of free triiodothyronine the commutability of control materials should be tested if they are to be used to normalize patient results obtained by different methods.

摘要

相似文献

1
Normalizing intermethod free triiodothyronine patient results: need for commutable materials.
Clin Chem Lab Med. 1998 Oct;36(10):777-80. doi: 10.1515/CCLM.1998.138.
2
Myoglobin and creatine kinase isoenzyme MB mass assays: intermethod behaviour of patient sera and commercially available control materials.
Clin Chim Acta. 2001 Jan;303(1-2):55-60. doi: 10.1016/s0009-8981(00)00370-3.
3
Intermethod variability of sodium and potassium results: patients' sera and commercially available control sera.
Eur J Clin Chem Clin Biochem. 1997 May;35(5):387-92. doi: 10.1515/cclm.1997.35.5.387.
4
Intermethod variation in serum carcinoembryonic antigen (CEA) measurement. fresh serum pools and control materials compared.
Clin Chem Lab Med. 2002 Feb;40(2):167-73. doi: 10.1515/CCLM.2002.029.
5
Commutability of calibration and control materials for serum lipase.
Clin Chem. 2001 Dec;47(12):2108-13.
6
The nature of calibrators in immunoassays: are they commutable with test samples? Must they be?免疫测定中校准品的本质:它们与测试样品具有互换性吗?有这个必要吗?
Scand J Clin Lab Invest Suppl. 1991;205:47-54. doi: 10.3109/00365519109104601.
7
Evaluation of commutability of control materials.
Clin Chem Lab Med. 2002 Jun;40(6):625-30. doi: 10.1515/CCLM.2002.108.
8
Inter-method differences and commutability of control materials for HbA2 measurement.
Clin Chem Lab Med. 2000 Oct;38(10):997-1002. doi: 10.1515/CCLM.2000.148.
9
A mechanism-based way to evaluate commutability of control materials for enzymatic measurements. The example of gamma-glutamyltransferase.基于机制的方法评估酶学测量用控制材料的互换性。以γ-谷氨酰转移酶为例。
Clin Chim Acta. 2013 Sep 23;424:153-8. doi: 10.1016/j.cca.2013.06.012. Epub 2013 Jun 18.
10
Impact of reference materials on accuracy in clinical chemistry.
Clin Biochem. 1998 Aug;31(6):449-57. doi: 10.1016/s0009-9120(98)00054-x.