The two-period repeated measurements crossover design is often used in clinical trials. In this article we give a formula for sample size determination for testing treatment effect in two-period repeated measurements crossover design by taking an analysis of variance approach to the repeated measurements analysis. A balanced situation is considered: two treatment sequences that have the same number of patients, and the time points of measurements on each subject within each treatment period equal in number. The formula reveals the relationship between the required number of patients for each treatment sequence, the number of repeated measurements within each treatment period, the detectable treatment difference with respect to a primary response variable, and the power for testing the treatment difference. A clinical trial example is given to illustrate the use of the formula.
两阶段重复测量交叉设计常用于临床试验。在本文中,我们给出了一个样本量确定公式,用于通过采用方差分析方法对重复测量进行分析,来检验两阶段重复测量交叉设计中的治疗效果。考虑一种平衡情况:两个治疗序列的患者数量相同,且每个治疗期内每个受试者的测量时间点数量相等。该公式揭示了每个治疗序列所需患者数量、每个治疗期内重复测量的次数、相对于主要反应变量可检测的治疗差异以及检验治疗差异的功效之间的关系。给出了一个临床试验实例来说明该公式的应用。