Suppr超能文献

使用流体传导系统对两种根尖充填材料微渗漏的纵向研究。

Longitudinal study of the microleakage of two root-end filling materials using a fluid conductive system.

作者信息

Yatsushiro J D, Baumgartner J C, Tinkle J S

机构信息

Department of Endodontology, Oregon Health Sciences University, School of Dentistry, Portland, USA.

出版信息

J Endod. 1998 Nov;24(11):716-9. doi: 10.1016/S0099-2399(98)80160-X.

Abstract

A comparison of the microleakage of mineral trioxide aggregate (MTA) and a high copper admix amalgam (Valiant PhD) in root-end preparations was made using a fluid conductive device. Thirty-three bilaterally matched pairs of extracted, single-rooted teeth were prepared and obturated using lateral compaction of gutta-percha. The root-ends were resected and 3-mm-deep class I cavity preparations were made. The root-end preparations were filled with either amalgam or MTA. Guttapercha coronal to the root-end fillings was removed leaving only the amalgam or MTA present as a barrier to fluid movement. In the fluid-conductive device, the root canals were filled with a phosphate-buffered saline solution at a pressure of 10 psi. The flow of fluid was measured and compared at 1, 2, 3, 4, 8, 12, 16, 20, and 24 wk. The results showed amalgam to have significantly higher microleakage after 4 wk and higher variability compared with the MTA group.

摘要

使用流体传导装置比较了矿物三氧化物凝聚体(MTA)和高铜混合汞合金(Valiant PhD)在根尖制备中的微渗漏情况。制备了33对双侧匹配的单根离体牙,采用侧向加压热牙胶进行根管充填。切除根尖,制备3mm深的I类洞。根尖制备物分别用汞合金或MTA充填。去除根尖充填物上方的牙胶,仅保留汞合金或MTA作为流体移动的屏障。在流体传导装置中,根管内充满压力为10 psi的磷酸盐缓冲盐水溶液。在1、2、3、4、8、12、16、20和24周时测量并比较流体流量。结果显示,与MTA组相比,汞合金在4周后微渗漏显著更高,且变异性更大。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎