Berthou J, Chrétien F C, Driguez P A
Laboratoire de Minéralogie-Cristallographie associé au CNRS (LA 009, Université P. et M. Curie, Paris.
Contracept Fertil Sex. 1998 Nov;26(11):781-9.
Copper release from copper-bearing IUD's was studied in vitro and in vivo using atomic absorption spectrophotometry in deionized water, normal saline solution and normal ovulatory cervical mucus. In these media, copper release from a 375 mm2 DIU occurs without latency, showing comparable amounts for identical time intervals. Daily copper release was shown to be respectively 8 and 11 times higher in cervical mucus and normal saline solution than in deionized water. Although copper ions are detectable in ovulatory cervical mucus under physiological conditions, the copper content appears 5 to 6 times higher in women bearing a copper IUD. Obviously, the copper amount is dependent on the copper exposed surface: the daily in vitro release from a 250 mm2 IUD is 18% inferior to that observed from a 375 mm2 model. In vivo, the daily copper release in ovulatory mucus of 380 or 200 mm2 IUD users is respectively 5 and 3.5 times higher than in controls.