Brunnenberg M, Lindenblatt H, Gouzoulis-Mayfrank E, Kovar K A
Pharmaceutical Institute of the University of Tübingen, Germany.
J Chromatogr B Biomed Sci Appl. 1998 Nov 20;719(1-2):79-85. doi: 10.1016/s0378-4347(98)00396-x.
A HPLC method has been developed for the analogue of Ecstasy MDE and its major metabolites N-ethyl-4-hydroxy-3-methoxyamphetamine (HME) and 3,4-methylenedioxyamphetamine (MDA) in human plasma. In the course of our investigations we found that the methylenedioxyamphetamines and HME exhibit fluorescence at 322 nm. Therefore the detection could be carried out with a fluorescence (FL) detector. Solid-phase extraction was used for sample preparation and yielded high recovery rates greater than 95%. The limit of quantitation for MDE and its metabolites in the extracts was between 1.5 and 8.9 ng/ml and the method standard deviations were less than 5%. This sensitive, rapid and reliable analytical method has been used successfully in the quantitation of the substances in plasma samples obtained from 14 volunteers in two clinical studies after p.o. administration of 100 to 140 mg MDE*HCI. The maximum plasma concentrations were 235-465 ng/ml (MDE), 67-673 ng/ml (HME) and 7-33 ng/ml (MDA), respectively. Pharmacokinetic parameters have been investigated using the plasma concentration curves.
已开发出一种高效液相色谱法,用于测定人体血浆中摇头丸类似物3,4-亚甲基二氧甲基苯丙胺(MDE)及其主要代谢物N-乙基-4-羟基-3-甲氧基苯丙胺(HME)和3,4-亚甲基二氧苯丙胺(MDA)。在我们的研究过程中,我们发现亚甲基二氧苯丙胺类化合物和HME在322nm处有荧光。因此,可以使用荧光(FL)检测器进行检测。采用固相萃取法制备样品,回收率高于95%。提取物中MDE及其代谢物的定量限在1.5至8.9ng/ml之间,方法标准偏差小于5%。这种灵敏、快速且可靠的分析方法已成功用于两项临床研究中对14名志愿者口服100至140mg MDE*HCl后采集的血浆样本中这些物质的定量分析。最大血浆浓度分别为235 - 465ng/ml(MDE)、67 - 673ng/ml(HME)和7 - 33ng/ml(MDA)。已使用血浆浓度曲线研究了药代动力学参数。