A multiresolution restoration method for cardiac SPECT imaging.

作者信息

Franquiz J M, Shukla S

机构信息

Department of Nuclear and Radiological Engineering, University of Florida, Gainesville 32611, USA.

出版信息

Med Phys. 1998 Dec;25(12):2469-75. doi: 10.1118/1.598462.

Abstract

In this study we present a multiresolution based method for restoring cardiac SPECT projections. Original projections were decomposed into a set of sub-band frequency images by using analyzing functions localized in both the space and frequency domain. This representation allows a simple denoising and restoration procedure by discarding high-frequency channels and performing inversion only in low frequencies. The method was evaluated in bull's eye reconstructions of a realistic cardiac chest phantom with a custom-made liver insert and 99mTc liver-to-heart activity ratios (LHAR) of 0:1, 1.5:1, 2.5:1, and 3.5:1. The cardiac phantom in free air was used as the reference standard. Reconstructions were performed by filtered backprojection using (1) no correction; (2) restoration without attenuation correction; (3) attenuation correction without restoration; and (4) restoration and attenuation correction. The attenuation correction was carried out with the Chang's method for one iteration. Results were compared with those obtained using an optimized prereconstruction Metz filter. Quantitative analysis was performed by calculating the normalized chi-square measure and mean +/- s.d. of bull's eye counts. In reconstructions with high liver activity (LHAR > 2), attenuation correction without restoration severely distorted the polar maps due to the spill-over of liver activity into the inferior myocardial wall. Both restoration methods when combined with an attenuation correction compensated this artifact and yielded uniform polar maps similar to that of the standard reference. There was no visual or quantitative difference between the performance of Metz filtering and multiresolution restoration. However, the main advantage of the multiresolution method is that it states a more concise and straightforward approach to the restoration problem. Multiresolution based methods does not require information about the object image or optimization processes, such as in conventional nuclear medicine restoration filters. In addition, the method is easy to implement using DFT techniques and potentially can be extended to noniterative spatially shift-invariant restorations in SPECT.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验