Suppr超能文献

Passive transmission of ischemic ST segment changes in low electrical resistance myocardial infarct scar in the pig.

作者信息

Cinca J, Warren M, Rodríguez-Sinovas A, Tresànchez M, Carreño A, Bragós R, Casas O, Domingo A, Soler-Soler J

机构信息

Laboratorio de Cardiología Experimental, Hospital General Universitari Vall d'Hebron, Universitat Autònoma de Barcelona, Spain.

出版信息

Cardiovasc Res. 1998 Oct;40(1):103-12. doi: 10.1016/s0008-6363(98)00145-x.

Abstract

OBJECTIVES

To analyze the passive electrical properties of a healed infarction and assess their role on transmission of contiguous ischemic ST segment potential changes.

METHODS

We measured tissue resistivity (omega cm) at 1 kHz and the epicardial ST segment during 1 h of proximal reocclusion of the left anterior descending (LAD) coronary artery in 12 anesthetized pigs with one-month-old transmural infarction elicited by LAD ligature below the first branch. The impedance spectrum (1 to 1000 kHz) of normal and infarcted myocardium was measured in seven other pigs with similar infarctions. Electrical transmission of current pulses (30 microA) in infarcted tissue and in test solutions was also investigated.

RESULTS

The infarct scar has a lower than normal resistivity (110 +/- 30 omega cm vs. 235 +/- 60 omega cm, p < 0.0001) and, unlike the normal myocardium, resistivity and phase angle of the scar did not change at increasing current frequencies, reflecting no capacitative response. LAD reocclusion induced a resistivity rise (510 +/- 135 omega cm, p < 0.01) and a ST segment elevation (0.6 +/- 0.7 to 9.5 +/- 5.1 mV, p = 0.002) in the ischemic peri-infarction zone, whereas the infarcted area showed ST segment elevation (0.5 +/- 0.5 to 3.8 +/- 2.6 mV, p = 0.03) with no resistivity changes. Potential decay of both ST segment and current pulses in the scar and in 0.9% NaCl solution was less than 1 mV/mm. Transmural deposition of connective tissue was seen in the center of the infarction.

CONCLUSIONS

A one-month-old transmural infarction is a low resistance, noncapacitative medium that allows a good transmission of current pulses and of ST segment potential changes generated by contiguous peri-infarction ischemia.