Suppr超能文献

40%氟化银溶液商业制剂中氟化物水平异常高:儿童使用的禁忌证

Abnormally high fluoride levels in commercial preparations of 40 per cent silver fluoride solution: contraindications for use in children.

作者信息

Gotjamanos T, Orton V

机构信息

Department of Pathology and School of Oral Health Sciences, University of Western Australia.

出版信息

Aust Dent J. 1998 Dec;43(6):422-7. doi: 10.1111/j.1834-7819.1998.tb00203.x.

Abstract

Although a 40 per cent solution of silver fluoride would be expected to contain 6 per cent fluoride (60,000 ppm), F-levels of 100,000 ppm and 120,000 ppm were found in 14 commercial samples analysed at The University of Western Australia in 1993 and 1994. To determine whether F-levels in 40 per cent AgF preparations have remained high, the present investigation was aimed at analysing different batches of commercial preparations obtained more recently. Fluoride ion analysis was carried out on 24 AgF samples using the Ion-Selective Electrode technique. Independent analyses of the same samples were carried out by a private chemical testing laboratory (Genalysis). Ten samples supplied by Agson Chemical Export were found to contain between 75,000 and 100,000 ppm F-: Genalysis reported 80,000 to 120,000 ppm. Fourteen samples supplied by Southern Dental Industries were found to contain between 70,000 and 120,000 ppm F-; Genalysis reported 88,000 to 108,000 ppm F-. These results confirm significantly higher than expected F-levels (ANOVA p < 0.05) in commercial preparations of 40 per cent AgF. The solutions tested were found to contain a mixture of ammonium fluoride, sodium or potassium fluoride, and silver fluoride. The additional presence of silver difluoride and hydrofluoric acid resulting from the manufacturing process has been suggested as an explanation for the much higher than expected levels of fluoride ion. In view of possible toxicity of 40 per cent AgF in young children, it is concluded that such a highly concentrated solution should not be used clinically; instead, lower strength AgF solutions should be investigated for their efficacy in caries treatment.

摘要

虽然预计40%的氟化银溶液应含有6%的氟化物(60,000 ppm),但1993年和1994年在西澳大利亚大学分析的14个商业样品中发现氟含量分别为100,000 ppm和120,000 ppm。为了确定40%氟化银制剂中的氟含量是否仍然很高,本研究旨在分析最近获得的不同批次的商业制剂。使用离子选择电极技术对24个氟化银样品进行了氟离子分析。由一家私人化学检测实验室(Genalysis)对相同样品进行了独立分析。发现由Agson化学出口公司提供的10个样品中氟含量在75,000至100,000 ppm之间;Genalysis报告的氟含量为80,000至120,000 ppm。发现由南方牙科工业公司提供的14个样品中氟含量在70,000至120,000 ppm之间;Genalysis报告的氟含量为88,000至108,000 ppm。这些结果证实,40%氟化银商业制剂中的氟含量显著高于预期(方差分析p < 0.05)。测试的溶液被发现含有氟化铵、氟化钠或氟化钾以及氟化银的混合物。有人认为,制造过程中额外产生的二氟化银和氢氟酸是氟离子含量远高于预期水平的原因。鉴于40%氟化银对幼儿可能有毒性,得出的结论是,这种高浓度溶液不应在临床上使用;相反,应研究较低浓度的氟化银溶液在龋齿治疗中的疗效。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验