Schmidt F, Mannsåker T, Løvlie R
Tidsskr Nor Laegeforen. 1999 Feb 10;119(4):491-4.
In this experimental study, 35 males were exposed to artificial magnetic fields. The fields were produced by a set of Helmholz coils internally isolated by a Faraday cage which effectively eliminated electrical fields. Each participant stayed inside the coils for 40 minutes on two occasions with an interval of seven days, but was actually only once exposed to a static magnetic field (9.6 mT) and oscillating magnetic fields of variable frequency and strength. Urine and blood samples were taken before and after exposure, and before and after non-exposure. Analysis detected significant changes in serum creatinine level after exposure (p < 0.0001). The changes in serum creatinine level in the nonexposed situation were significantly smaller than the changes found in the exposed situation (p < 0.0001). The changes i urine creatinine after 40 minutes of exposure was also found to be significant (p < 0.01). Exposure to magnetic fields may induce biological reactions.