Suppr超能文献

Problems and pitfalls in the performance and interpretation of color Doppler flow imaging: observations based on the influences of technical and physiological factors on the color Doppler examination of mitral regurgitation.

作者信息

Rao S R, Richardson S G, Simonetti J, Katz S E, Caldeira M, Pandian N G

机构信息

Departments of Medicine and Radiology, Tufts-New England Medical Center, Boston, MA 02111.

出版信息

Echocardiography. 1990 Nov;7(6):747-62. doi: 10.1111/j.1540-8175.1990.tb00427.x.

Abstract

Color Doppler flow imaging has become an integral part of the echocardiographic examination. By providing real-time, two-dimensional spatial maps of normal and abnormal cardiac blood flows, this technique provides important information that may be used to guide patient management. The acquisition and display of color Doppler flow information may be influenced by technical factors, by the physiological condition of the patient, by abnormalities of cardiac morphology, and, on occasion, by artifact. In this article, the results of a study performed to evaluate the influence of technical factors on the color Doppler assessment of mitral regurgitation are reported. Mitral regurgitation jet area size changed significantly with variation in the control settings for color gain, color process, color map, color image resolution, and sector width. A review of those factors that influence the performance and interpretation of the color Doppler flow examination is provided and their significance discussed.