Suppr超能文献

健康受试者N2闭合气量试验的日变化及可重复性

Diurnal variations and reproducibility of the N2 closing volume test in healthy subjects.

作者信息

Marcq M, Minette A

出版信息

Bull Eur Physiopathol Respir. 1976 Nov-Dec;12(6):757-70.

PMID:1016803
Abstract

To assess the diurnal variation of closing volume measurements, 11 non-smokers and 10 somkers, all healthy, were tested with the single-breath nitrogen test. In each subject, 3 satisfactory tracings were recorded at 9:a.m., 11:a.m., 1:p.m., 3:p.m. and 5:p.m. on each of two consecutive days. Duplicate copies of the tracings were read in radom order by two independent observers. The "best+ and the mean values of closing volume to vital capacity ratio (CV/VC or phase 4/VC) and of the slppe of phase 3 were calculated. The study shows that: (1) the time of the day may be a source of variation of the closing volume measurements. Meals and cigarette smoke did not appear to be responsible for this diurnal variation, (2) values obtained with the "best" tracing method can, at least in some readers, give systematic differences with the mean of several traces, (3) individual variations in CV/VC and in the slope of phase 3 are the highest with the "best" trace analysis, and (4) the vlaues obtained by two independent readers may significantly differ. The differences observed between hours, although significant, were nevertheless small in magnitude and did not explain most of the variation of the measurements. Variations in trace aspect were small in some subjects. The reproducibility of the test was remarkable in them, at least when the junction of phase 4 with phase 3 was well defined. In other subjects, the coefficient of variation was high mainly because of varying curve shape and/or poorly defined departure of phase 4. This explains for a great part the intra-and interreader variations observed in this study.

摘要

为评估闭合气量测量的日变化情况,对11名不吸烟者和10名吸烟者(均为健康者)进行了单次呼吸氮试验。在每位受试者身上,于连续两天中的每一天的上午9点、11点、下午1点、3点和5点记录3份满意的描记图。两名独立观察者以随机顺序读取描记图的副本。计算了闭合气量与肺活量比值(CV/VC或第4相/VC)以及第3相斜率的“最佳”值和平均值。研究表明:(1)一天中的时间可能是闭合气量测量变化的一个来源。进餐和香烟烟雾似乎不是这种日变化的原因,(2)至少在一些读者中,用“最佳”描记方法获得的值可能与几条描记图平均值存在系统差异,(3)采用“最佳”描记分析时,CV/VC和第3相斜率的个体差异最大,(4)两名独立读者获得的值可能存在显著差异。各时间点之间观察到的差异虽然显著,但幅度较小,且不能解释测量值的大部分变化。在一些受试者中,描记图形态的变化较小。至少当第4相与第3相的交界处清晰时,该试验在这些受试者中的可重复性很显著。在其他受试者中,变异系数较高,主要是因为曲线形状变化和/或第4相的起始界定不清。这在很大程度上解释了本研究中观察到的读者内和读者间的差异。

相似文献

5
Closing capacity measurement during general anesthesia.
Anesthesiology. 1976 Nov;45(5):477-82.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验