Tripolt H, Burstone C J, Bantleon P, Manschiebel W
Department of Orthodontics, University of Vienna, Austria.
Am J Orthod Dentofacial Orthop. 1999 May;115(5):498-507. doi: 10.1016/s0889-5406(99)70271-4.
Nickel-titanium closed coil springs are commonly used for space closure. The springs possess a high resistance to permanent deformation and the potential for relatively constant force delivery. A study was designed to determine whether relatively constant forces can be delivered and whether the force magnitudes approach the manufacturer's targeted force values. Heavy, medium, and light springs were activated 15 mm at temperatures that ranged from 15 degrees C to 60 degrees C. The forces were measured during deactivation with a specially constructed force transducer temperature chamber. Relatively constant forces can be achieved with an over-activation procedure that allows relaxation to the desired activation. The light springs delivered forces that were near the targeted force; no difference was found between the heavy and medium springs in the constant force range. The force magnitudes varied markedly depending on mouth temperature.
镍钛闭合螺簧常用于间隙关闭。这些弹簧具有高抗永久变形能力以及提供相对恒定力的潜力。一项研究旨在确定是否能提供相对恒定的力,以及力的大小是否接近制造商的目标力值。重型、中型和轻型弹簧在15摄氏度至60摄氏度的温度范围内激活15毫米。在通过特制的力传感器温度室去激活过程中测量力。通过过度激活程序使弹簧松弛至所需激活状态可实现相对恒定的力。轻型弹簧施加的力接近目标力;在恒定力范围内,重型和中型弹簧之间未发现差异。力的大小根据口腔温度有显著变化。