一种压力限制型重症监护呼吸机。

A pressure-limited critical care ventilator.

作者信息

Morris A H, Myers T

出版信息

Respir Care. 1987 Mar;32(3):172-7.

PMID:10315728
Abstract

We developed a new pressure-limited ventilator system by modifying the Bird #7001M ventilator. Our aims were to free ICU floor space by wall-mounting the ventilator, and to employ a pressure-limited, gas-powered ventilator similar to our transport ventilator to aid in the training of members of our transport team. The system provides a peak pressure of 150 cm H2O and a peak flow of 208 L/min. When coupled with heated pneumatic nebulizers, it quietly provides a maximum gas flow of 208 L/min with nebulized water at 37 degrees C. We successfully used this system for over 4 years to provide a wide range of ventilatory support and oxygen therapy.

摘要

我们通过对Bird #7001M呼吸机进行改造,开发了一种新型压力限制通气系统。我们的目标是通过将呼吸机壁挂安装来节省重症监护病房的地面空间,并使用一种类似于我们的转运呼吸机的压力限制、气体驱动的呼吸机,以帮助培训我们转运团队的成员。该系统提供的峰值压力为150 cm H2O,峰值流量为208 L/min。当与加热气动雾化器配合使用时,它能在37摄氏度的雾化水条件下安静地提供高达208 L/min的最大气体流量。我们成功地使用该系统超过4年,以提供广泛的通气支持和氧疗。

相似文献

1
A pressure-limited critical care ventilator.一种压力限制型重症监护呼吸机。
Respir Care. 1987 Mar;32(3):172-7.
2
A comparison of the CPAP performance characteristics of the Puritan-Bennett 7200a and a prototype continuous pressure-regulating ventilator.普瑞美德-贝内特7200a型持续气道正压通气(CPAP)设备与一款原型持续压力调节呼吸机的性能特征比较
Respir Care. 1994 Mar;39(3):195-203.
3
Modified ventilator with liquid-oxygen system for transport of adult patients with acute respiratory failure.
Respir Ther. 1979 Nov-Dec;9(6):35-42.
4
Laboratory and clinical evaluation of the impact Uni-Vent 750 portable ventilator.Uni-Vent 750便携式呼吸机影响的实验室及临床评估
Respir Care. 1992 Jan;37(1):29-36.
5
Pressure support and pressure assist/control: are there differences? An evaluation of the newest intensive care unit ventilators.压力支持与压力辅助/控制:有区别吗?对最新重症监护病房呼吸机的评估。
Respir Care. 2000 Oct;45(10):1169-81.
6
Evaluation of inspiratory rise time and inspiration termination criteria in new-generation mechanical ventilators: a lung model study.新一代机械通气机吸气上升时间和吸气终止标准的评估:一项肺模型研究
Respir Care. 2001 Jul;46(7):666-77.
7
Variations in tidal volume with portable transport ventilators.便携式转运呼吸机潮气量的变化
Respir Care. 1992 Mar;37(3):233-9.
8
Air medical transport in 1991.
Respir Care. 1992 Jul;37(7):796-803; discussion 803-6.
9
Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.吸气时间对压力控制模式下麻醉和重症监护病房呼吸机潮气量输送的影响。
J Clin Anesth. 2005 Feb;17(1):8-15. doi: 10.1016/j.jclinane.2004.02.005.
10
Comparative bench study of triggering, pressurization, and cycling between the home ventilator VPAP II and three ICU ventilators.家用呼吸机VPAP II与三台重症监护室呼吸机之间触发、增压及循环的对比实验台研究。
Intensive Care Med. 2002 Sep;28(9):1254-61. doi: 10.1007/s00134-002-1421-4. Epub 2002 Aug 1.